OPERATING PROCEDURES
6-11
Model C612
Operating Procedures
6
9. With a pail beneath the door spout, open the draw
valve and press the Pump key
. Open the draw
valve and draw off the sanitizing solution. Open and
close the draw valve six times.
10. Press the Wash
and Pump
keys to stop
the Wash and Pump modes and then close the draw
valve. (See Figure 6-45.)
Figure 6-45
Important!
The machine must
not
be placed in Auto until
all sanitizing solution has been removed from the
freezing cylinder and proper priming procedures have
been completed. Failure to follow this instruction may
result in damage to the freezing cylinder.
Note:
Make sure your hands are clean and sanitized
before continuing these instructions.
11. Place the agitator on the agitator driveshaft housing.
Figure 6-46
Note:
If agitator should stop turning during normal
operation, with
sanitized hands,
remove agitator
from agitator driveshaft housing and brush-clean with
sanitizing solution. Install the agitator back onto the
agitator driveshaft housing.
12. Remove the cotter pin from the pump. Stand the mix
feed tube in the corner of the mix hopper. Place the
cotter pin in position in the outlet fitting of the pump.
Figure 6-47
Note:
You have just sanitized all food contact surfaces
on the shake side of the freezer.
Sanitizing—Soft Serve Side
1. Prepare two pails of an approved 100 ppm sanitizing
solution (examples: 2-1/2 gal. [9.5 L] of Kay-5
®
or
2 gal. [7.6 L] of Stera-Sheen
®
).
Important!
Use warm water and follow the
manufacturer's specifications.
2. Pour one pail of the sanitizing solution over all the
parts in the bottom of the mix hopper and allow it to
flow into the freezing cylinder.
Note:
You have just sanitized the mix hopper and
parts. Therefore, make sure your hands are clean
and sanitized before continuing these instructions.
While the solution is flowing into the freezing cylinder,
take particular care to brush-clean the mix-level
sensing probes, mix hopper, mix inlet hole, outside of
agitator housing, agitator, air/mix pump, pump clip,
mix feed tube, and cotter pin.
Содержание C612
Страница 8: ...1 4 TO THE INSTALLER Model C612 To the Installer 1 Notes...
Страница 54: ...9 2 PARTS REPLACEMENT SCHEDULE Model C612 Parts Replacement Schedule 9 Notes...
Страница 58: ...10 4 LIMITED WARRANTY ON EQUIPMENT Model C612 Limited Warranty on Equipment 10 Notes...
Страница 62: ...11 4 LIMITED WARRANTY ON PARTS Model C612 Limited Warranty on Parts 11 Notes...