1-4
TO THE INSTALLER
Models 345, 346, 349, 355
To the Installer
1
Note:
The following procedures must be performed by
an authorized Taylor service technician.
Initial Freezing Cylinder Cleaning
Due to the types of products used in FCB equipment, it is
imperative that the freezing cylinder and the inlet tube be
thoroughly brush-cleaned, rinsed, and sanitized before
running any product.
Prepare a cleaning solution, using 2 oz. of liquid
detergent in 2 gal. of warm water. Using this solution,
brush-clean the freezing cylinder and the inlet tube.
Rinse the freezing cylinder and the inlet tube with clean
water and then sanitize, using the sanitizing procedures
outlined in this Operator Manual, starting on page 6-6.
Refrigerant
CAUTION!
This equipment contains
fluorinated greenhouse gases (F-Gas) to provide
refrigeration using a hermetically sealed circuit or within
foam insulation. This unit's type of gas, quantity, Global
Warming Potential (GWP) and CO
2
tonnes equivalent
information are recorded on the unit's data-label. The
refrigerant used is generally considered non-toxic and
non-flammable. However any gas under pressure is
potentially hazardous and must be handled with caution.
NEVER
fill any refrigerant cylinder completely with liquid.
Filling the cylinder to approximately 80% will allow for
normal expansion
CAUTION!
Use only approved refrigerant
listed on the unit's data label or authorized through a
manufacturer's technical bulletin. The use of any other
refrigerant may expose users and operators to
unexpected safety hazards.
IMPORTANT!
Refrigerants and their
associated lubricants may be extremely moisture
absorbent. When opening a refrigeration system, the
maximum time the system is open must not exceed 15
minutes. Cap all open tubing to prevent humid air or
water from being absorbed by the oil.
WARNING!
Refrigerant liquid sprayed onto the
skin may cause serious damage to tissue. Keep eyes
and skin protected. If refrigerant burns should occur,
flush them immediately with cold water. If burns are
severe, apply ice packs and contact a physician
immediately.
NOTICE!
Taylor reminds technicians to be
aware of and in compliance with local government laws
regarding refrigerant recovery, recycling, and reclaiming
systems. For information regarding applicable local laws,
please contact your local authorized Taylor distributor.
Syrup System Connections
1. Water pipe connections and fixtures directly
connected to a potable water supply shall be sized,
installed, and maintained according to federal, state,
and local laws.
2. Hook up the cold water supply to the freezer to
supply water to the carbonator. A minimum of 21 psi
(1.45 bar) of water pressure is required at the low-
pressure switch. The low-pressure switch will cause
the entire freezer to shut down if the water pressure
drops below 7 psi (0.483 bar) for longer than 1
minute.
The water regulator should be set at 35 PSI
(2.41 bar). When the power switch is turned on the
water pump will immediately activate to maintain
water pressure.
!
!