Bonus Plus Instructions Tarm Biomass 1-800-782-9927 Version 11/14 Page 45
6.3 Specification Data
*6” with flue collar adaptor. Specifications subject to change.
Data and Drawings > Specification Data
Technical Data
Units
30
MEASUREMENTS
Depth- Boiler -Total
inches
43
Width- Boiler -Total
inches
23
Height to Chimney Connection
inches
28
Flue Collar Outside Diameter
inches
5*
Weight- Empty
lbs
825
Water Contents
gals
31.7
Loading Door
inches
13¾ X 12
Combustion Chamber Depth
inches
21¼”
Combustion Chamber Volume
gals
cubic ft.
23.7
3.2
Recommended Wood Length
inches
18-20
Wood Diameter (Max)-Softwood
inches
4
Wood Diameter (Max)-Hardwood
inches
6
OPERATING DATA
Operating Temperature-Water
Fº
180-190
Nominal Output
Btu/Hr
102,000
Flue Gas Temperature at Nominal Output
Fº
363
Required Draft
inch WC
-.025” to -.05”
Safety Listings
-
UL 2523-2009
ELECTRICAL DATA
Boiler Power Requirement
-
120V-60Hz/15A
Electrical Consumption
W
70
PIPING DATA
Boiler Test Pressure
psi
65
Boiler Relief Valve Setting
psi
30
Supply & Return Pipe Stub Size (male NPT)
inches
1
Minimum Boiler Loop size
inches
1¼
Fill/Drain Valve Size
inches
½”
Mixing Valve Opening Setting
Fº
140
Internal Overheat Aquastat Setting
Fº
212
Fig. 6.2