Bonus Plus Instructions Tarm Biomass 1-800-782-9927 Version 11/14 Page 32
Boiler Operation, Maintenance, and Service > Cleaning and Maintenance
WARNING
Before performing any cleaning or maintenance on the boiler, allow boiler to completely
burn through all fuel and to normally cool down and shut off.
Turn off power to the boiler
before performing any cleaning or maintenance.
WARNING
Ashes removed from the boiler should be placed in a metal container with a tightly fitting
lid The closed container of ashes should be placed on a non-combustible floor or on the
ground, well away from all combustible materials, pending final disposal. If the ashes are
disposed of by burial in soil or otherwise locally dispersed, they should be retained in the
closed container until all cinders have thoroughly cooled. Other waste should not be
placed in this container.
4.10 Cleaning and Maintenance
4.10.1 Removing Ash
Regular maintenance (cleaning) of the boiler is the responsibility of the owner. An annual inspection
by a heating professional is required.
A metal brush with a bent handle and
an ash pan are supplied with the boiler.
The ash pan is to be placed on the
floor in front of the ash door. The
edge of the ash pan fits just under
the lower lip of the ash door opening
as shown in photo.
Fig. 4.8
Содержание Bonus Plus 30