Bonus Plus Instructions Tarm Biomass 1-800-782-9927 Version 11/14 Page 23
3.4.9 Installing the Overheat Aquastat
The Honeywell L4008B aquastat provided with this boiler must be installed and wired in parallel with
the thermostat on the zone with the most heating capacity in the main living area (dump zone). Upon
reaching the aquastat set point, the dump zone will be activated, pulling heat away from the boiler.
Boiler Installation & Start-up > Connections to the Boiler
Remove left knock-out on side panel.
The side panel can now be re-installed.
The Honeywell L6006A aquastat can now
be attached to sensor well. (Note: Image
does not show side panel installed.)
Find the spare sensor well #8 located on
the top of the boiler (located on the right
side of boiler). Remove the existing sen-
sor well.
Replace with new ½” sensor well.
The bulb for the Honeywell L4008B over-
heat aquastat can now be installed. Top
panel can also be re-installed.