StorageLibrary Installation and User Guide
75
Table 11. Troubleshooting Matrix Media with Solution
Problem
Solution
Media
Media barcode labels
Make sure the barcode labels are applied in the correct
orientation on the cartridge. See
Labeling Cartridges for the
Barcode Reader
.
Make sure there are no wrinkles on the label.
Make sure that StorageLibrary specific labels are used.
If all of the above are OK, replace the label with a new one.
If problem continues, contact your service representative.
Data cartridge incompatible with
drive
Make sure you are using a data cartridge that is compatible
with the drive. See the tape drive s reference manuals for
details.
The SW backup application detects if an incompatible data
cartridge is used, and communicates this to the user.
Remove the cartridge from the library.
Cannot write to or read from
tape
Make sure that the cartridge is write enabled (move the write-
protect switch to the enabled position).
Make sure that the cartridge has not been written using an
incompatible format.
Make sure that the cartridge is an acceptable format for your
drive type. See the tape drive s reference manuals for details.
Make sure that the cartridge has not been exposed to harsh
environmental or electrical conditions and is not physically
damaged in any way.
Many backup applications do not read or write to cartridges
that were created using a different backup application. In this
case, you may have to perform an erase, format, or label
operation on the cartridge.
Make sure you understand any data protection or overwrite
protection schemes that your backup application may be
using, which could prevent you from writing to a given
cartridge.
Retry the operation with a different, known good tape.
Clean the tape drive. See
Cleaning Tape Drives
.
Table 12. Troubleshooting Matrix SCSI with Solution
Problem
Solution
SCSI problems
Changed SCSI ID, but the host
server system does not
recognize the new ID
Make sure that all SCSI devices on the same bus have unique
ID numbers.
If the SCSI bus is narrow (50-pin) only SCSI IDs 0 through 7
are available.
Make sure that you reboot the library after changing the SCSI
ID.
Reboot the host server system.
The tape drive does not
respond on the SCSI bus to the
host
Verify that a SCSI terminator is attached to both the last and
first SCSI device on the SCSI bus.
Verify that the SCSI cables are connected to the rear of the
library. See
Connecting Library Cables (SCSI)
.
Содержание StorageLibrary T40 T40
Страница 1: ...InstallationandUser Guide...
Страница 28: ......
Страница 31: ...StorageLibrary Installation and User Guide 23 Figure 14 Front Panel Interface Menu Tree...
Страница 34: ...26 Information about the Operator Interfaces Figure 15 Remote Management Interface Top Level Menu Tree...
Страница 40: ......
Страница 64: ......
Страница 68: ...60 Adding Removing and Replacing Figure 24 Adding Removing or Replacing a Tape Drive...
Страница 71: ...StorageLibrary Installation and User Guide 63 From the FPI select Tools Drive Settings...
Страница 72: ......
Страница 92: ......