22
Tanco Autowrap 1300 S
Operator’s manual
7.3.7 Total
Reset
If for some reason the data in the instrument is corrupted or the display shows '
PrOg
' then the instrument must be
totally reset.
.
Switch power off.
.
Press and hold all 3 control switches.
.
Switch power on.
.
Release all switches.
All instrument settings should be returned to the factory-set values. If the display shows '
PrOg
' again, the
instrument may be faulty and must be returned to the manufacturer for inspection and repair.
Film Break Sensor – OROGRAMMING LEVEL 2
7.3.8 Programming Level 2
The 1300 S features Automatic Cut and start operation through the control unit. The
1300 SM also has an
autostop
feature which holds the joystick in position and
automatically releases it at the end of the wrap sequence. The settings of these features
are programmable in Level 2.
To enter, cut power and power on while holding CAL button. Release after power on.
Press and release CAL to advance chevron to next position
To escape from this calibration level, switch power off and on again.
Channel Function Default
Range
1
Over speed Alarm*
35
0-99
2
W – Delay after pulse 2 before X
0.5
0-9.9
3
X – C&S Open duration
0.5
0-9.9
4
Y – Delay after Target – 1 before C&S Open
1.0
0-9.9
5
Z – Duration of C&S Open after Target pulse
2.0
0-9.9
6
V – Autostop release delay
0.7
0.0-9.9
[*In normal operation - If the rotation speed in RPM exceeds this number during
operation, the alarm will sound for the duration of this condition.
Chevron will default to channel 6 and display will flash in this condition.
0.491 Secs Mark and Space. Chevron will revert to channel 1 when speed
drops below overspeed limit].