19
Tanco Autowrap 1300 S
Operator’s manual
7.3.1.3 Program Early Warning Alarm
An early warning alarm can be programmed to sound from 1 to 9 wraps before the target number is reached.
Depending on the setting, the alarm will sound long beeps for up to 8 wraps, short beeps for the final wrap, and then
a continuous beep for three seconds.
For example, if the bale requires 22 wraps and you want an alarm at 20 wraps, then set the number to 2.
To effectively disable the alarm, set the number to 0.
Press to select .
Hold continuously.
The fourth digit flashes.
Hold to cycle to the required digit.
Release all.
7.3.2 Channel 2 - Store Totals
When bale wrap is complete, one of eight pre-selected memory store totals
A
,
b
,
C
,
d
,
E
,
F
,
G
, or
H,
is
automatically advanced by 1. Store totals can be reset individually.
3.2.1
Display a Store Total
Press to select .
The fourth digit displays the current store designation for 2 seconds.
The current total for that store then displays for five seconds, then defaults to
channel 1.
3.2.2
Select a Store Total
Press to select .
Select the desired store total (A – H).
This is now the default store, and subsequent bale counts are stored there
until another store is selected.