Using via Digital Data Communication
92
[SOURce]:MEMory:RECall:MODE
: Sets Load Order for Panel Memory
Function:
Sets the order of loading for panel memory(A/B/C)
Same as FUNCTION Settings Item 54
Format:
[SOURce]:MEMory:RECall:MODE <NRf>
Type:
SET command, QUERY command
Parameters:
0: Determines by Single-Action
1: Determines by Double-Action
Response:
Same as parameters
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a series operation slave unit
·
While operating as a parallel operation slave unit
<Ex.>
MEM:REC:MODE 1
MEM:REC:MODE?
1
[SOURce]:MEMory:STORe
: Saves to Panel Memory
Function:
Saves to panel memory(A/B/C)
Format:
[SOURce]:MEMory:STORe <String>
Type:
SET command only
Parameters:
A: Overwrites current settings to panel memory A
B: Overwrites current settings to panel memory B
C: Overwrites current settings to panel memory C
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a series operation slave unit
·
While operating as a parallel operation slave unit
<Ex.>
MEM:STOR A
Содержание HX-S-G4 Series
Страница 157: ...Special Loads 157 This page is blank...
Страница 161: ...Maintenance 161 This page is blank...
Страница 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Страница 198: ...Specifications 198 2 HX S 030 400G4 F I...
Страница 199: ...Specifications 199 3 HX S 060 100G4 F I...
Страница 200: ...Specifications 200 4 HX S 060 200G4 F I...
Страница 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Страница 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Страница 203: ...Specifications 203 7 HX S 01000 6G4 F I...
Страница 204: ...Specifications 204 8 HX S 01000 12G4 F I...