Using via Digital Data Communication
84
MEASure Level
MEASure level command corresponds to functions concerning measurement, such as retrieving voltage and current
measurements.
Command Name
Summary
Command Type
MEASure
-
-
:CORRection
-
-
:MODE
Sets operation mode for the Linear Compensation Function
Both
:MVAV
Sets Moving Average process for measurement values
Both
[:SCALar]
-
-
:CURRent
-
-
[:DC]
Retrieves current measurement values
QUERY Only
:VOLTage
-
-
[:DC]
Retrieves voltage measurement values
QUERY Only
:POWer
-
-
[:DC]
Retrieves power measurement values
QUERY Only
MEASure:CORRection:MODE
:Sets operation mode for the Linearity Compensation Function
Function:
Sets the operation mode for the Linearity Compensation Function
Same as FUNCTION Settings Item 12
Format:
MEASure:CORRection:MODE <NRf>
Type:
SET command, QUERY command
Parameters:
0: Compensation OFF
1: Executes only when Output is toggled ON/OFF or when there is a setting change
2: Continual compensates
Response:
Same as parameters
Restrictions:
Alarm response is returned for normal SET commands in the following conditions
·
While operating as a parallel operation slave unit
<Ex.>
MEAS:CORR:MODE 0
MEAS:CORR:MODE?
0
Содержание HX-S-G4 Series
Страница 157: ...Special Loads 157 This page is blank...
Страница 161: ...Maintenance 161 This page is blank...
Страница 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Страница 198: ...Specifications 198 2 HX S 030 400G4 F I...
Страница 199: ...Specifications 199 3 HX S 060 100G4 F I...
Страница 200: ...Specifications 200 4 HX S 060 200G4 F I...
Страница 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Страница 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Страница 203: ...Specifications 203 7 HX S 01000 6G4 F I...
Страница 204: ...Specifications 204 8 HX S 01000 12G4 F I...