Useful Function
50
When selecting Constant Voltage (CV) Priority and Variable Slew Rate mode (Item 1 set to 3),
Set to 2 or 3 using the VOLTAGE dial.
Set Value 2 = Rising Voltage Slew Rate
Set Value 3 = Falling Voltage Slew Rate
Assign the set value using the CURRENT dial.
Range(EX): 0.01V/s to 30.00V/s (Resolution 0.01V/s)
When selecting Constant Current (CC) Priority and Variable Slew Rate mode (Item 1 set to 7),
Set to 4 or 5 using the VOLTAGE dial.
Set Value 4 = Rising Current Slew Rate
Set Value 5 = Falling Current Slew Rate
Assign the set value using the CURRENT dial.
Range (Ex)
0.1A/s to 400.0A/s (Resolution 0.1A/s)
If using in parallel operation, Constant Current (CC) Slew Rate in
page 49 should be referenced.
Press the FUNC. key again to finish.
Confirms settings and returns the Number Display to
measurement display mode.
It is possible to continue to change other setting items
without pressing the “FUNC.” key. In this case, press the
“FUNC.” key to confirm settings once changes are complete.
MEMO
* The figure above is an example of
connecting (HX030-200G4)
* The figure above is an example of
connecting (HX030-200G4)
* The figure above is an example of
connecting (HX030-200G4)
Содержание HX-S-G4 Series
Страница 157: ...Special Loads 157 This page is blank...
Страница 161: ...Maintenance 161 This page is blank...
Страница 197: ...Specifications 197 External Diagrams 1 HX S 030 200G4 F I...
Страница 198: ...Specifications 198 2 HX S 030 400G4 F I...
Страница 199: ...Specifications 199 3 HX S 060 100G4 F I...
Страница 200: ...Specifications 200 4 HX S 060 200G4 F I...
Страница 201: ...Specifications 201 5 HX S 0500 12G4 F I...
Страница 202: ...Specifications 202 6 HX S 0500 24G4 F I...
Страница 203: ...Specifications 203 7 HX S 01000 6G4 F I...
Страница 204: ...Specifications 204 8 HX S 01000 12G4 F I...