51
Daily Inspections
If water is leaking from the pipes, the pipes or gasket
may be worn, degraded or damaged. Close the stop
valves in the water supply pipe and hot water supply
pipe [page 45, 46], and stop using the product immedi-
ately.
If water is leaking from the drain hose, the drain hose
may be damaged. Stop using the product immediately.
Use an item such as a toothbrush to remove any dirt
such as water scale and clean the spray nozzle. Leaving
the spray nozzle uncleaned will lead to blockage, and
water may not be output from the shower head proper-
ly.
Is there any water
leaking within the
basin?
Is there any water
leaking from the
drain hose?
Is there any water
scale or dirt blocking
the spray nozzle?
Remove the basin maintenance
cover and check that there is no
water leaking from the internal
pipes or water taps.
[page 45, 46]
Remove the basin maintenance
cover and check that there is no
water leaking from the drain hose.
[page 45, 46]
Remove the spray nozzle from the
shower head and check that there
is no water scale or dirt on it.
[page 42, 43]
Inspect item
Inspection method
If the inspection results show defects
Inspect the product once per week
Standard Duration of Use
The standard period of use of this product is seven years.
The standard period of use is "a guide for the standard period that this product can be used
properly from a safety perspective, when conducting appropriate maintenance and inspections
(including replacement of parts) for the standard usage conditions for each product."
This is not the same as the warranty period.
Parts Replaced on a Regular Basis
The following are parts that must be replaced on a regular basis as designated by our company:
□
Drain hose: Replace every three years
・
For the drain hose, there is a possibility that water leaks will occur because cracks are caused due to
deterioration and hardening of the hose from chemical agents in the drain water.
・
Damage to the hose may result in water flooding on or beneath the floor.
□
Check valve: Replace every three years
・
When the check valve is used continuously for long periods of time, there is a possibility that the
parts in the valve will deteriorate resulting in no water discharging, or sometimes, the sewage water
once discharged from the water faucet will flow back, thus causing contamination of city water or
public health problems.
□
Water/hot-water supply hose: Replace every three years
・
For the water/hot-water supply hose, there is a possibility that cracks due to deterioration caused by
equipment operation or residual chlorine or copper ions in the city water will cause water leaks.
・
Damage to the hose may result in water flooding on or beneath the floor.
The above-listed parts must be replaced on a regular basis to ensure and maintain safety and perfor-
mance.
Any part that is outside the designated replacement period must be replaced even if there is no problem
during use. (The parts are available at additional cost.) Our company will not assume responsibility for
any harm, damage, or defects attributed to any part that was not replaced within the designated period.
For ordering replacement work, contact your local Takara Belmont dealer.