33
LineOut;
Sync. Line Out1 Mixer:
Adjust the audio
parameters (Conference Management System -
Setup - Audio Output Setup) of LineOut1 and the
floor signal via Mixer 1 synchronously, see figure
2.1.12. This mode is used in the conference
room without PA.
In the three modes above, if ambient microphone
(used to pick up ambient sound in the congress
room) is enabled via software (Conference
Management System - Setup - Ambient Mic. Setup)
and this microphone is active, its signal is added to
the floor signal only. When any one microphone is
activated, the ambient microphone will be turned
off automatically.
b). Press the “MENU” button to save and return to the
upper level menu.
38. Lock CU LCD Lang. Setting
a). Press the “
/
” button to select “Yes” or “No”;
If select “
Yes
”, operation language of congress
unit, interpreter unit and operator unit cannot be
changed;
If select “
No
”, operation language of congress
unit, interpreter unit and operator unit can be
changed;
b). Press the “MENU” button to save and return to the
upper level menu.
39. Nameplates Setting
Select turn on the HCS-1030 nameplate which is not
assigned delegate unit or not.
a). Press the “
/
” button to select “Turn Off” or “Turn
On”;
b). Press the “MENU” button to save and return to the
upper level menu.
40. DDS Units Setting
Set work mode for HCS-xxxxDDS:
a). Press the “
/
” button to select “Turn Off” or “Turn
On”;
Single ID:
one HCS-xxxxDDS owns one ID and
dual predefined positions; two delegates may
share one unit;
Double ID:
one HCS-xxxxDDS owns double IDs
and each predefined position for each ID; two
delegates may share one unit;
b). Press the “MENU” button to save and return to the
upper level menu.
41. Retractable Mic. Setting
Control the array microphone of HCS-4851/50 series
retractable microphone.
a). Press the “
/
” button to select “Control” or “Sync
Number”;
If select “
Control
”, use the “MENU” button to go
to step b);
If select “
Sync Number
”, use the “MENU” button
to go to step c);
b). Press the “
/
” button to select “Retract” or
“Raise”;
c). Press the “
/
” button to set sync number from 1
to 6;
Note:
Please restart the CMU to enable the DDS
units setting.
Содержание HCS-4100MA/50
Страница 50: ...35 Figure 2 1 10 Floor mode setting Normal Mode Figure 2 1 11 Floor mode setting Insert Mode...
Страница 51: ...36 Figure 2 1 12 Floor mode setting Sync Line Out1 Mixer...
Страница 67: ...52 Figure 3 2 6 Installation diagram of HCS 48U6SPK...
Страница 79: ...64 3 3 2 Installation 3 3 2 1 Cutout Figure 3 3 2 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 80: ...65 Figure 3 3 3 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 81: ...66 Figure 3 3 4 Cutout of HCS 48U9 series flush mounted congress unit unit mm...
Страница 82: ...67 Figure 3 3 5 Cutout of HCS 48U7MICSPK flush mounted congress unit unit mm...
Страница 83: ...68 3 3 2 2 Installation Figure 3 3 6 Installation of HCS 48U7 series flush mounted congress unit...
Страница 84: ...69 Figure 3 3 7 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 85: ...70 Figure 3 3 8 Installation of HCS 48U7MICSPK series flush mounted congress unit...
Страница 87: ...72 Figure 3 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 100: ...85 3 4 2 Installation Figure 3 4 2 Cutout of HCS 48U10 series congress unit unit mm...
Страница 101: ...86 Figure 3 4 3 Installation of HCS 48U10 series congress unit...
Страница 162: ...147 3 10 2 Installation Figure 3 3 2 Installation of HCS 4851 50 series congress unit unit mm...
Страница 163: ...148 Figure 3 3 3 Installation of HCS 4851 50 series congress unit...
Страница 181: ...166 Figure 3 12 3 Installation of HCS 4325U 50 congress unit unit mm...
Страница 196: ...181 Figure 3 13 7 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 212: ...197 Figure 3 14 18 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 225: ...210 3 16 2 Installation Figure 3 16 2 Installation of HCS 1080 electronic nameplate...
Страница 230: ...215 4 1 HCS 4385U 50 4 1 1 Functions and indications Front Side Bottom Figure 4 1 1 HCS 4385U 50 Interpreter unit...
Страница 243: ...228 4 2 HCS 8385 60 4 2 1 Functions and indications Front Side Bottom Figure 4 2 1 HCS 8385 60 Interpreter unit...
Страница 275: ...260 HCS 1020 clip microphone...
Страница 316: ...301 Appendix Custom made cable Appendix Dedicated 6 PIN Extension Cable...