3.15.4 Operation
Before a meeting starts, the congress units must be
configured by the operator, including: numbering and
testing. During the meeting, the participators use the
voting unit to sign-in and to vote.
3.15.4.1 Delegate unit
We introduce all the operation of HCS-4368/50 series
congress units. The congress units of this series
feature one or more of these functions.
1. Number
First of all, make sure that all congress units are
connected properly to the CMU. All congress units
must be numbered when the system is used for the first
time or when adding or replacing congress units. The
numbering function can be activated by menu
operation on the CMU front panel or by application
software.
Select “Number” by menu operation from the CMU,
press the “MENU” key to confirm, following the system
goes to numbering status.
“Press ’1’ key of all congress
units one by one and repower”
will be displayed on the
CMU LCD. The number indicating light of all connected
voting units will blink. All voting units with the LCD will
display “Numbering”. Press key “1” of all voting units
one by one. The number indicating light will be
deactivated. Once all voting units numbered, restart the
CMU to update the number information.
2. Sign-in
(application software needed)
To carry out voting, congress units with voting and
IC-Card reader should be registered via key press,
IC-Card or input PIN code. With application software,
registration is available by choosing “Seat Sign-in”.
Key-press sign-in
In key-press sign-in status, the indicating light on key
“1” will blink, press key “1” to sign-in and the indicating
light will be turned off.
IC-Card sign-in
In IC-Card sign-in status, “Please Use IC Card” will be
displayed on the LCD. Read the IC-Card correctly, a
welcome interface will be displayed. Press any key to
go to the initial interface. If the IC-Card is invalid,
“Invalid IC card” will be displayed on the LCD. Please
read the IC-Card again or contact the technical
support.
PIN code sign-in
In PIN code sign-in status, “Input PinCode” will be
displayed on the LCD. Input PIN code and select the
“
” button to confirm. If the PIN code is correct, the
LCD will display the delegate’s name; if the PIN code is
wrong, the PIN code sign-in interface displayed on the
LCD again.
Icon:
♦
0
,
1
,
2
,
3
,
4
,
5
,
6
,
7
,
8
,
9:
PIN code number;
♦
:
backspace;
♦
:
enter;
Key:
♦
“
1
” key: move left;
♦
“
3
” key: move right;
♦
“
5
” key: confirm button.
Note:
When numbering, please number the
congress units one by one and do NOT press
the “NUMBER” key of several congress units
at the same time.
Содержание HCS-4100MA/50
Страница 50: ...35 Figure 2 1 10 Floor mode setting Normal Mode Figure 2 1 11 Floor mode setting Insert Mode...
Страница 51: ...36 Figure 2 1 12 Floor mode setting Sync Line Out1 Mixer...
Страница 67: ...52 Figure 3 2 6 Installation diagram of HCS 48U6SPK...
Страница 79: ...64 3 3 2 Installation 3 3 2 1 Cutout Figure 3 3 2 Cutout of HCS 48U7 series flush mounted congress unit unit mm...
Страница 80: ...65 Figure 3 3 3 Cutout of HCS 48U8 series flush mounted congress unit unit mm...
Страница 81: ...66 Figure 3 3 4 Cutout of HCS 48U9 series flush mounted congress unit unit mm...
Страница 82: ...67 Figure 3 3 5 Cutout of HCS 48U7MICSPK flush mounted congress unit unit mm...
Страница 83: ...68 3 3 2 2 Installation Figure 3 3 6 Installation of HCS 48U7 series flush mounted congress unit...
Страница 84: ...69 Figure 3 3 7 Installation of HCS 48U8 series and HCS 48U9 series flush mounted congress unit...
Страница 85: ...70 Figure 3 3 8 Installation of HCS 48U7MICSPK series flush mounted congress unit...
Страница 87: ...72 Figure 3 3 11 Disassembly caution of HCS 48U8 and HCS 48U9 series flush mounted congress unit...
Страница 100: ...85 3 4 2 Installation Figure 3 4 2 Cutout of HCS 48U10 series congress unit unit mm...
Страница 101: ...86 Figure 3 4 3 Installation of HCS 48U10 series congress unit...
Страница 162: ...147 3 10 2 Installation Figure 3 3 2 Installation of HCS 4851 50 series congress unit unit mm...
Страница 163: ...148 Figure 3 3 3 Installation of HCS 4851 50 series congress unit...
Страница 181: ...166 Figure 3 12 3 Installation of HCS 4325U 50 congress unit unit mm...
Страница 196: ...181 Figure 3 13 7 Multi function connector connected to the HCS 4341 50 series congress unit...
Страница 212: ...197 Figure 3 14 18 Multi function connector connected to HCS 4841 42 43 series congress units...
Страница 225: ...210 3 16 2 Installation Figure 3 16 2 Installation of HCS 1080 electronic nameplate...
Страница 230: ...215 4 1 HCS 4385U 50 4 1 1 Functions and indications Front Side Bottom Figure 4 1 1 HCS 4385U 50 Interpreter unit...
Страница 243: ...228 4 2 HCS 8385 60 4 2 1 Functions and indications Front Side Bottom Figure 4 2 1 HCS 8385 60 Interpreter unit...
Страница 275: ...260 HCS 1020 clip microphone...
Страница 316: ...301 Appendix Custom made cable Appendix Dedicated 6 PIN Extension Cable...