Common Sentinel Pro Configuration Errors
The following table describes possible consequences of wrongly defined parameters
in the Sentinel Pro Setup table. (For a description of these parameters, see
Table 14 Sentinel Pro
Configuration Errors
Parameter
Error
Possible
Impact
Cause
WAN RTP
Base Port
Correct value, but
the firewall is not set
up to support at
least the required
number of ports
Impaired RTP
sessions
Transmission of RTP
packets does not
function when more
ports are used than
allowed in the firewall.
Other value than
3000 or 16400 (only
relevant if used with
Coral Version 14)
No RTP
sessions
Not Applicable.
Private Self
IP Address
Base Virtual
IP Address
The same IP
address is defined
for these two fields.
Packet loss,
reception of
wrong packets
Messages are sent
randomly to one of the
two devices.
Automatic
Sentinel Pro
reset
The unit does not
receive Keep Alive
messages from the
Coral and assumes
the connection is lost.
Base Virtual
IP Address
# of Virtual
IP
Addresses
The defined IP
address range
includes one or more
already used IP
addresses.
Packet loss,
reception of
wrong packets
Messages are sent
randomly to one of the
devices with the same
IP address.
Registrar 1
Wrong or missing
value
Irrelevant error
Proxy 1
Irrelevant error
Call Agent
1...10
Wrong or missing
values in all Call
Agent fields
MGCP devices
are not
registered and
do not work.