48
WY05-4780E
Y-8.
Y-8.
Operation Check (Crane Operation)
10. Over-unwinding detection check
(option)
Check that the over-unwinding detection activates
and the winch stops when the wire rope on the
winch drum decreases to or below 3 turns.
11. Eco mode operation check
[NOTICE]
For the location of the switch, refer to “Z-10 Electric
Parts Location Diagram (Upper), 1. Inside cab”.
While the PTO is engaged, select the Eco mode 1
and Eco mode 2, and depress the accelerator
pedal fully. Then check that the maximum engine
speed lowers while the respective mode is
selected.
Eco mode
Max. engine speed (min
-1
)
OFF
Approx. 1900
1
Approx. 1550
2
Approx. 1350
Use the AML to select the Eco mode 1 or Eco
mode 2. The maximum engine speeds above
listed are for reference.
△