62
Operator´s manual BIO bale processor B4000
5.8 Service functions
Service function screens offer parameters that may be changed/configured by service people from the
Factory/sales company/importer organisation.
The service functions can be activated when the Joystick Function key & Joystick Down switch combina-
tion are activated at the same time in the Idle mode. The screens that appear are listed in the next
section. Stepping to the next screen can be accomplished by operating the joystick. Moving the joystick
to the right will step to the next screen, stepping to the previous screen is done by moving the joystick to
the left. When a parameter has to be changed/edited, activate any of the four edit switches: clear (C
switch), plus (joystick up), minus (joystick down) or equal (=/OK switch).
Pressing the STOP key in any step of this mode will finish the editing/monitoring and return to Idle mode
screen.
5.8.1 Service functions activated
This screen shows the user that the Service function screens are
activated.
5.8.2 Pin code
Only authorised service people are allowed to make changes to the
service level parameters, therefore a pin code protection is added in
the service function screens.
5.8.3
Setting the crop cutting system
14/23
Preselects 14 or 23 blades.
The following values concern the OptiCut23 system only:
23in Duration of hydraulic pressure when blades are swung in (recommended value = 4.0 s)
23out Duration of hydraulic pressure when blades are swung out (recommended value = 9.0 s)
5.8.4 Sensor time-out
This parameter configures the overall sensor timeout value. In the
automatic or manual cycle sensors are used to detect certain posi-
tions or conditions. If due to e.g. a sensor failure this signal does not
come the cycle would wait “forever” for the signal to come. Therefore
a parameter is added which is used as an overall “safe” timeout
value. If a sensor timeout occurs during a process cycle this will be
presented on the control panel by an error code in the screen (more
on this later) and an alarm beep.
5.8.5 Chamber bottom section set-up
The parameters of the discharge cycle are set here. This time
should be set to a value, which allows the bale to be dropped onto
the field properly before bottom section is returning to raised
position again. The time can be programmed in steps of 0.1 sec. Up
is the time where cylinder remain activated after having reached end
position in order to activate the check valve.
The computerised control system
5.8.6 Film cutter timing
In this screen the parameters for the film cutters can be configured.
Tf = film release time, steps of 25millisec (the time the cutters open
during the film release)
2f = ring position at second film release (w = half ring laps)
Ts = time where cutter cylinders remain activated after sensor position has been detected
(cutter closed).
Содержание BIO+ B4000
Страница 2: ...2 Operator s manual BIO bale processor B4000 ...
Страница 13: ...13 Fig 2 Fig 1 Fig 3 Fig 4 Fig 6 Fig 5 Fig 7 Fig 8 Safety ...
Страница 15: ...15 Fig 10 Fig 9 Fig 11 Fig 12 Fig 13 Safety ...
Страница 75: ...75 ...
Страница 76: ...76 Operator s manual BIO bale processor B4000 Notes Notes ...
Страница 77: ...77 ...