74
Operator´s manual BIO bale processor B4000
7.2.1 Sensors’ position
See overviews on next page. When a sensor is activated the red light (at the cable entrance) is
on.
The gap between sensor and inducting steel/magnet should be 3-6 mm.
Sensors
Sensor Positioned
Function
A
Rh side at ring support
Indicating prestretchers in safe sector
B
Rh side at ring motor
Exact stop position of prestretchers
C
Rh side at top section joint
Indicating top section completely raised
C
Rh side at top section joint
Indicating top section completely lowered
E
Rh side at chamber lock
Indicating chamber full
F
Rh side at net feeding roller
Indicating net feeding
G
Rh side at net knife releaser
Indicating net cutting knife release
H
Rh side at ring support
Indicating bottom roller section raised
I
Rh side integrated in actuator
Actuator positioning
J
Rh side on film cutter
Indicating film cutter closed
K
Lh side of blade holder
Swings cutting blades in and out