T011S ver. tS2111
www.tecnoautomazione.com
Pag. 2 / 17
INPUTS FUNCTIONS
PIN PARAMETER
DISABLED –
START (NO)
– OPEN (NO) –
CLOSE (NO) – DOMUS (NO)
1
8
E1
DISABLED –
STOP (NC)
– DOMUS (NO, NC)
2
8
E2
DISABLED –
EXT.PHOTOCELL (NC)
–
DOMUS (NO, NC)
3
8
E3
DISABLED –
INT. PHOTOCELL (NC)
–
EXT. PHOTOCELL (NC) - DOMUS (NO, NC)
4
8
E4
DISABLED –
CLOSING LIMIT SWITCH (NC)
–
CLOSING LIMIT SWITCH (NO) – DOMUS (NO, NC)
5
8
E5
DISABLED –
OPENING LIMIT SWITCH (NC)
–
OPENING LIMIT SWITCH (NO) – DOMUS (NO, NC)
6
8
E6
DISABLED –
PEDESTRIAN (NO)
– OPEN (NO) –
CLOSE (NO) – DOMUS (NO)
7
8
E7
BOARD’S
COMPONENTS
A
Button A
B
Button B
C
Button C
D
Button D
F1
250 VAC power fuse 5A
F4
Resettable fuse 24V 1.6A
F5
Resettable fuse 24V 0.6A
A B C Ground terminals
CN
Primary varistor
V1
Secondary varistor
V2
Terminal block pins
1 to 20 Button A
RESETTABLE FUSE
AFTER A SHORT-CIRCUIT:
•
TURN OFF THE
CONTROL BOARD.
REMOVE THE SHORT-
CIRCUIT.
•
WAIT FOR 60
SECONDS OR MORE.
TURN ON THE
CONTROL BOARD.
F4/F5
INPUTS CONNECTION
OUTPUTS CONNECTION
DOMUS
Multi functions module (optional)
ELSER
12 Volt Electric lock module (optional)
MOTORS
CLOSE
COMMON
OPEN
Motor A
13
14
15
FLASHING LAMP 24V 20W
24VDC 300 mA
11
12
8
+
10
-
PHOTOCELLS
24V DC
TYPE
PIN
PARAMETER
+
-
EXTERNAL
TX
9
10
E3
RX
8
10
N.C.
3
8
INTERNAL
TX
9
10
E4
RX
8
10
N.C.
4
8