FORCE-OBSTACLE SENSOR CALIBRATION
TABLES
The obstacle sensor stops or reverts the gate movement if an obstacle has been detected. The parameters
A5
and
A6
set the
motor force and the sensor sensitivity. The parameters
A7
and
A8
are the sensor calibration in standard and slowdown
mode, respectively. A lower force value means a higher sensitivity, a higher force value means a lower sensitivity. The
following tables show the values of
A5
,
A6
,
A7
,
A8 B8
/
for electric gate motor models M2-500, M2-800 and M2-1500.
www.tecnoautomazione.com
Pag. 14 / 17
STANDARD MODE SENSOR CALIBRATION
ELECTRIC GATE MOTOR
FORCE
M2 – 500
M2 – 800
M2 – 1500
A5 b5
/
A7 b7
/
A7 b7
/
A7 b7
/
1
→
no
no
no
2
→
80
83
no
3
→
76
82
no
4
→
71
81
no
5
→
73
66
no
6
→
51
37
no
7
→
53
38
no
8
→
52
41
26
9
→
58
47
31
10
→
64
54
36
STANDARD MODE SENSOR CALIBRATION
ELECTRIC GATE MOTOR
FORCE
M2 – 500
M2 – 800
M2 – 1500
A6 b6
/
A8 b8
/
A8 b8
/
A8 b8
/
1
→
no
no
no
2
→
no
no
no
3
→
no
no
no
4
→
no
no
78
5
→
no
no
79
6
→
80
81
80
7
→
80
80
82
8
→
80
78
85
9
→
82
75
84
10
→
79
75
81