FUNCTIONS
RECOVERY CYCLE
L4
L4
=
SI
→ ENABLED
L4
=
no
→ DISABLED
This function can be enabled to open/close the gate in case of failure of one of the safety
devices (photocells or stop). This function requires the installation of a start device
(normally open contact) on the terminal block 1 or 7 and the setting of the parameter (
E1
or
E7
)
to one of the following functions:
Go
start,
oP
open,
CL
close. If this function
has been enabled and a safety device (stop, internal or external photocell) has been
active for more than 5 seconds, the gate can be opened/closed following four easy steps:
1. Turn on the start device
2. Turn off the start device. The flashing lamp will turn on.
3. Turn on the start device within 2.5 sec from the flashing of the flashing lamp. The
display will start the countdown (from 2.5 seconds to 0).
4. The gate will move in the chosen direction (opening/closing) until the start device
is on. To stop the gate turn off the start device.
FOR SAFETY REASONS, IT IS HIGHLY RECOMMENDED TO ENABLE THE
L4
FUNCTION
ONLY ON WIRED DEVICES (I.E. KEY SELECTORS).
TEST
PHOTOCELLS TEST
t1
t1
=
SI
→ ENABLED
t1
=
no
→ DISABLED
Each time the gate starts, the control board checks the photocells. If no errors are
detected the motors can be started. Vice versa the motors cannot start and the control
board display shows
1t
.
MOTORS
TEST
t2
t2
=
SI
→ ENABLED
t2
=
no
→ DISABLED
Before each gate movement the motor is tested. If the motor is in thermal protection
state or it is badly connected the display shows
9A
. When the test fails the gate does not
move.
PRE-PROGRAMMED CONFIGURATIONS
FACTORY
CONFIGURATION
d0
Keep pressing button A or B until the display shows
d0
. The control board shows
no
. To
set the factory settings hold down button C until the display shows
--
. The factory
configuration does not have any effect on radio memory.
MOTOR A
TERMINAL BLOCK INPUTS
FUNCTIONS
A1
STANDARD WORKING TIME
14 s
E1
INPUT 1
Go
START NO
F0
AUTOMATIC CLOSURE
10 s
A2
SLOWDOWN WORKING TIME
7 s
E2
INPUT 2
5t
STOP NC
F1
PEDESTRIAN WORKING TIME
7 s
A3
START UP TIME
0.8 s
E3
INPUT 3
tC
EXT. PHOTOCELLS NC
F2
KICK BACK CLOSING
0.0 s
A5
STANDARD FORCE
6/10
E4
INPUT 4
tA
INT. PHOTOCELLS NC
F4
PRE-BLINKING TIME
1.0 s
A6
SLOWDOWN FORCE
10/10
E5
INPUT 5
FC
CL. LIMIT SWITCH NC
F5
STEP-BY-STEP
no
A7
STANDARD OBSTACLE
no
E6
INPUT 6
FA
OP. LIMIT SWITCH NC
F6
COMMUNITY MODE
no
A8
SLOWDOWN OBSTACLE
no
E7
INPUT 7
PE
PEDESTRIAN NO
F7
RAPID CLOSURE
no
s
Seconds
m
Minutes
no
DISABLED
SI
ENABLED
F8
PHOTOCELLS LOGIC
SI
L0
ELECTRIC-LOCK
no
L1
COLD WINTER
0 m
L4
RECOVERY CYCLE
no