TA T011S Скачать руководство пользователя страница 3

INDEX

T011S ver. tS2111 ......................................................................................2

MENU NAVIGATION...................................................................................2

TROUBLE SHOOTING..................................................................................2

-- 

NONE.......................................................................................2

- 

REMOTE TRANSMITTING (REM)..............................................2

5t 

STOP (NC) (REM).....................................................................2

tC 

EXTERNAL PHOTOCELL (NC)....................................................2

tA 

INTERNAL PHOTOCELL (NC).....................................................2

FH 

INTERNAL AND EXTERNAL PHOTOCELLS..................................2

FC 

CLOSING LIMIT SWITCH (NC)...................................................2

FA 

OPENING LIMIT SWITCH (NC)..................................................2

LC 

CLOSING LIMIT SWITCH (NO)..................................................2

LA 

OPENING LIMIT SWITCH (NO).................................................2

1H 

LIMIT SWITCHES ERROR .........................................................2

Go 

START (NO) (REM)...................................................................2

PE 

PEDESTRIAN (NO) (REM).........................................................2

Eo 

DOMUS (NO)...........................................................................2

EC 

DOMUS (NC)............................................................................2

oC 

DOMUS REMOTE (REM)..........................................................2

1t 

PHOTOCELLS TEST ERROR........................................................2

9A 

MOTOR TEST ERROR................................................................2

7A 

OBSTACLE DETECTED...............................................................2

8A 

OBSTACLE DETECTED DURING SLOWDOWN  ..........................2

FF 

REMOTE MEMORY FULL..........................................................2

00

 to 

99 

MOTOR STRESS............................................................3

INSTALLING RADIO MODULE......................................................................3

TYPICAL INSTALLATION..............................................................................3

CONNECTIONS...........................................................................................4

GLOSSARY..................................................................................................5

STAND BY ..........................................................................................5
OPENING ...........................................................................................5
PAUSE................................................................................................5
CLOSING ............................................................................................5
STOP OPENING ..................................................................................5
STOP CLOSING....................................................................................5
CLOSING ............................................................................................5
INPUT IS ACTIVATED ..........................................................................5
START COMMANDS ...........................................................................5
SAFETY COMMANDS .........................................................................5
STANDARD WORKING CYCLE..............................................................5
PEDESTRIAN WORKING  CYCLE...........................................................5

MOTOR......................................................................................................6

A1 

STANDARD WORKING TIME.....................................................6

A2 

SLOWDOWN WORKING TIME..................................................6

A3 

START UP TIME .......................................................................6

A5 

STANDARD FORCE...................................................................6

A6 

SLOWDOWN FORCE................................................................6

A7 

STANDARD OBSTACLE DETECTION THRESHOLD.......................6

A8 

SLOWDOWN OBSTACLE DETECTION THRESHOLD....................6

SENSOR OPERATING MODE........................................................................7

FUNCTIONS................................................................................................8

F0 

AUTO-CLOSE TIME...................................................................8

F1 

PEDESTRIAN WORKING  TIME.................................................8

F2 

CLOSING KICK..........................................................................8

F3 

BLINKING TIME........................................................................8

F4 

KICK BACK AT OPENING...........................................................8

F5

 and 

F6

 STANDARD, COMMUNITY MODE, STEP BY STEP ..........8

F7 

FAST CLOSURE.........................................................................8

F8 

PHOTOCELLS LOGIC.................................................................8

L0 

ELECTRIC LOCK........................................................................8

L1 

COLD WINTER FUNCTION........................................................8

FUNCTIONS................................................................................................9

L4 

RECOVERY CYCLE.....................................................................9

TEST...........................................................................................................9

t1 

PHOTOCELLS TEST...................................................................9

t2 

MOTOR TEST...........................................................................9

PER-PROGRAMMED CONFIGURATIONS......................................................9

d0 

FACTORY CONFIGURATION......................................................9

REMOTE...................................................................................................10

r0 

SINGLE ERASE........................................................................10

STORING A REMOTE ........................................................................10
         

r1 

START...........................................................................  10

         

r2 

STOP..............................................................................10

         

r3 

PEDESTRIAN..................................................................10

         

r4 

FAST CLOSURE...............................................................10

r5 

ERASING ALL    ......................................................................10

TERMINAL BLOCK INPUTS........................................................................11

no 

DISABLED...............................................................................11

5t 

STOP (NC)..............................................................................11

tC 

EXTERNAL PHOTOCELL (NC)..................................................11

tA 

INTERNAL PHOTOCELL (NC)...................................................11

Go 

START (NO)............................................................................11

PE 

PEDESTRIAN (NO)..................................................................11

oP 

OPEN (NO) ............................................................................11

CL 

CLOSE (NO)............................................................................11

FA 

OPENING LIMIT SW.(NC)........................................................11

LA 

OPENING LIMIT SW.(NO).......................................................11

FC 

CLOSING LIMIT SW.(NC).........................................................11

LC 

CLOSING LIMIT SW.(NO)........................................................11

Eo

     DOMUS (NO).........................................................................11

EC

     DOMUS (NC).........................................................................11

PROGRAMMING PROCEDURE..................................................................12

         

P1 

SEMI-AUTOMATIC PROGRAMMING..............................12

         

P3 

AUTOMATIC PROGRAMMING........................................12

FORCE-OBSTACLE SENSOR CALIBRATION TABLES......................................13

INTRODUCTION DOMUS MODULE...........................................................14

 

www.tecnoautomazione.com

                                                                                                                                                                              Pag.  1 / 17

Содержание T011S

Страница 1: ...3DOLDQR 5 WDO RFDOLWj HUYLQDUD 7HO D 9LD 9LFLQDOH VQF LQIR WHFQRDXWRPD LRQH FRP ZZZ WHFQRDXWRPDWLRQ FRP 7 7HFQR XWRPD LRQH V U O A K M 7 W M J 7 M K A b M J 7HO HTSYWTQ ZSNY KTW XQNINSL LFYJX 86 5 0 1...

Страница 2: ......

Страница 3: ...E 6 A6 SLOWDOWN FORCE 6 A7 STANDARD OBSTACLE DETECTION THRESHOLD 6 A8 SLOWDOWN OBSTACLE DETECTION THRESHOLD 6 SENSOR OPERATING MODE 7 FUNCTIONS 8 F0 AUTO CLOSE TIME 8 F1 PEDESTRIAN WORKING TIME 8 F2 C...

Страница 4: ...NTS A Button A B Button B C Button C D Button D F1 250 VAC power fuse 5A F4 Resettable fuse 24V 1 6A F5 Resettable fuse 24V 0 6A A B C Ground terminals CN Primary varistor V1 Secondary varistor V2 Ter...

Страница 5: ...block input 7 is activated Parameter E7 is set to PE PEDESTRIAN A remote stored as r3 PEDESTRIAN START function is transmitting Eo DOMUS NO Terminal blocks inputs 1 2 3 4 or 7 are activated Parameters...

Страница 6: ...INSTALLATION www tecnoautomazione com Pag 4 17 RADIO BODY BODY RADIO BASE LIGTHS max 10W 24V COVER COVER ANTENNA COVER ANTENNA BASE Screws and stops not included 3 5mm x 13mm 3 5mm x 13mm 4 mm x 35mm...

Страница 7: ...VAC E1 DISABLED no START Go OPEN oP CLOSE CL E2 DISABLED no STOP 5t E5 DISABLED no CLOSING LIMIT SWITCH N C FC CLOSING LIMIT SWITCH N A LC E6 DISABLED no OPENING LIMIT SWITCH N C FA OPENING LIMIT SWIT...

Страница 8: ...r remote key is activated when it is pushed down All these actions are recognized by the control board which shows these changes on the display When more inputs are activated at the same time the cont...

Страница 9: ...dard working time A1 If the control board detects a motor stress higher than A7 it means that there is an obstacle in the way of the gate The control board will make a decision in accordance with its...

Страница 10: ...detection mode If the opening limit switch input is not installed E6 no and the opening is in progress The sensor works in obstacle detection mode during the standard working time A1 During the slowd...

Страница 11: ...t opening once the external photocells have been activated the gate will start to close after 5 seconds For safety reasons it is advisable to enable this function only when two pairs of external photo...

Страница 12: ...ors are detected the motors can be started Vice versa the motors cannot start and the control board display shows 1t MOTORS TEST t2 t2 SI ENABLED t2 no DISABLED Before each gate movement the motor is...

Страница 13: ...The motor works for a total time of A1 plus A2 seconds during the opening and the closing r2 STOP The stop function stops the gate r3 PEDESTRIAN The pedestrian function begins a Pedestrian Working Cyc...

Страница 14: ...al photocells does not have any effect N C SAFETY DEF INTERNAL PHOTOCELL NC Go The START function begins a STANDARD WORKING CYCLE The gate opens for A1 plus A2 slowdown seconds stays open for F0 secon...

Страница 15: ...To go to F0 press any start input F0 The pause time is being programmed F0 The gate is stopped The flashing lamp is on After 1 5 seconds the control board display shows the counting time To finish th...

Страница 16: ...ivity The following tables show the values of A5 A6 A7 A8 B8 for electric gate motor models M2 500 M2 800 and M2 1500 www tecnoautomazione com Pag 14 17 STANDARD MODE SENSOR CALIBRATION ELECTRIC GATE...

Страница 17: ...hts can be controlled by terminal block input remote key and or gate status The most useful functions are ON ON OFF ON from 0 to 99 Seconds Minutes Hours DOMUS controls up to 3 lights The lights can b...

Страница 18: ...NOTES www tecnoautomazione com Pag 16 17...

Страница 19: ......

Страница 20: ...86 5 0 18 a 1 VHMS A 7b MJ 0 1 7 3DOLDQR 5 WDO RFDOLWj HUYLQDUD 7HO D 9LD 9LFLQDOH VQF LQIR WHFQRDXWRPD LRQH FRP ZZZ WHFQRDXWRPDWLRQ FRP 7 7HFQR XWRPD LRQH V U O A K M 7 W M J 7 M K A b M J 7HO J XMTU...

Отзывы: