INPUTS
Each terminal block input has a control parameter. The control parameter sets the input function.
The control parameters are:
E1
→
input 1
,
E2
→
input 2
,
E3
→
input 3
,
E4
→
input 4
,
E5
→
input 5
,
E6
→
input 6
, and
E7
→
input 7
.
d
DEF.
= FACTORY SETTING
N.C.
= NORMALLY CLOSED
N.O.
= NORMALLY OPEN
SAFTEY
= SAFETY FUNCTION
FUNCTIONS
DESCRIPITION
TIPO
E1
in 1
E2
in 2
E3
in 3
E4
in 4
E5
in 5
E6
in 6
E7
in 7
no
Disable the chosen input. The inputs
E2
,
E3
and
E4
have the
auto-enable function.
When the terminal block
input is disabled and a normally closed contact is wired to
the input, the control board sets that input equal to the
SAFETY
value. For instance, if
E2
is set to
no
and a
normally closed contact is wired to input 2, the control
board sets
E2
to
5t
.
▪
▪
auto
enable
▪
auto
enable
▪
auto
enable
▪
▪
▪
DISABLED
St
The
stop function
stops the gate movement.
N.C.
SAFETY
▪
DEF.
STOP (NC)
tC
During the closing:
the
external photocells
stop the
closing and start the opening.
During the opening:
the
external photocells
do not have
any effect.
N.C.
SAFETY
▪
DEF.
▪
EXTERNAL
PHOTOCELL (NC)
tA
D
uring the opening:
The internal photocell stops the
opening and starts the closing. After 2 seconds the closure
is stopped. A start command restore the closing.
During the closing:
the
internal photocells
does not have
any effect.
N.C.
SAFETY
▪
DEF.
INTERNAL
PHOTOCELL (NC)
Go
The
START
function begins a
STANDARD WORKING CYCLE:
The gate opens for
A1
plus
A2
(slowdown) seconds, stays
open for
F0
seconds, and then closes.
N.O.
▪
DEF.
START (NO)
PE
The
PEDESTRIAN START
function begin a
PEDESTRIAN
WORKING CYCLE
: the gate opens for
F1
seconds.
N.O.
▪
DEF.
PEDESTRIAN (NO)
oP
The
open
function opens the gate.
When the control board is in stand by state the
open only
function begins a
Standard Working Cycle
.
N.O.
▪
▪
OPEN
(NO)
CL
The
close
function closes the gate. This command works
when the control board state is not in stand by. It works in
stand by state every time the control board is restarted.
N.O.
▪
▪
CLOSE (NO)
FA
The
OPENING LIMIT SWITCH
terminates the opening phase.
N.C.
▪
DEF.
OP. LIMIT SW.(NC)
LA
The
OPENING LIMIT SWITCH
terminates the opening phase.
Set this function if you are using
magnetic limit switches
codes:
FNCMF5T
.
N.O.
▪
OP. LIMIT SW.(NO)
FC
The
CLOSING
LIMIT SWITCH
terminates the closing phase.
Set this function if you are using
magnetic limit switches
codes:
FNCMF5T
.
N.C.
▪
DEF.
CL. LIMIT SW.(NC)
LC
The
CLOSING
LIMIT SWITCH
terminate the closing phase.
N.A.
▪
CL. LIMIT SW.(NO)
Eo
DOMUS (NO)
The
domus command
does not have any effect on the gate
status. It can be used in combination with the
domus
expansion.
For instance a light can be turned on through
the key selector without starting the gate.
N.O.
▪
▪
▪
▪
▪
▪
▪
EC
DOMUS (NC)
N.C.
▪
▪
▪
▪
▪