FUNCTIONS
AUTO-CLOSE TIME
The gate remains open for
F0
seconds at the end of opening before begging the closing phase.
To disable hold down
@
C button until display shows
St
.
F0
PEDESTRIAN
WORKING TIME
It is the motor working time during a pedestrian working cycle. The slowdown phase is skipped during the
opening and executed during the closing. The slowdown time is automatically managed by the control
board during a pedestrian working cycle.
F1
CLOSING KICK
When the gate is closing and the slowdown is finished, a ramp pulse of
F2
seconds is executed by motor
A to facilitate locking of the electric lock.
F2
BLINKING TIME
Before starting the motor, the flashing lamp blinks for
F3
seconds. After this time the flashing lamp will
continue blinking and the motor will start.
F3
KICK BACK AT
OPENING
F4
=
SI
→ ENABLED
F4
=
no
→ DISABLED
Before opening the motor closes for 0.5 seconds to facilitate the release of the electric lock.
F4
START COMMANDS
FUNCTIONALITY
STANDARD MODE
F6
=
no
and
F5
=
no
During the opening
:
The start commands stop the
opening.
During the closing
:
The start commands stop the
closing and begin the opening.
COMMUNITY MODE
F6
=
SI
During the opening
:
The start commands don't have
any effect.
During the closing
:
The start commands stop the
closing and begin the opening.
STEP-BY-STEP MODE
F6
=
no
and
F5
=
SI
During the opening
:
The start commands stop the gate.
During the closing:
The start commands stop the gate.
F5
F6
FAST CLOSURE
If
F7
=
SI
→ All start commands begin the fast closure function.
If
F7
=
no
→ Only remote keys programmed through
r4
begin the fast closure function.
Fast closure means: During the first opening once the external photocells have been activated the gate
will start to close after 5 seconds.
For safety reasons it is advisable to enable this function only when two pairs of external photocells are
installed as shown in
TYPICAL INSTALLATION
.
F7
PHOTOCELLS LOGIC
F8
=
SI
→
SLIDING MODE
D
uring the opening:
If the internal photocell is activated the control
board stops the opening and starts the closing.
After 3 seconds the closure is stopped and the
control board state is stop-opening. The activation
of the external photocell doesn't have any effect
Instead.
During the closing:
If the external photocell is activated the control
board stops the closing and starts the opening.
The activation of the internal photocell doesn't
have any effect instead.
F8
=
no
→
SWING MODE
During the opening:
While the internal photocell is activated the control
board stops the opening. When the internal photocell is
deactivated the control board continues the opening. The
activation of the external photocell doesn't have any
effect instead.
During the closing:
If the external photocell is activated the control board
stops the closing and starts the opening.
If the internal photocell is activated the control board
stops the closing and waits for the opening. The opening
starts only when the internal photocell is deactivated.
F8
ELECTRIC LOCK
L0
=
SI
→ ENABLED
The electric-lock module is managed. The
module must be installed on the expansion
socket.
L0
=
no
→ DISABLED
The electric-lock is not managed. The module is not
installed on the expansion socket.
L0
COLD WINTER
FUNCTION
L1
is settable from 0 to 8 minutes. For instance, by setting
L1
to 3 that means that the motor will
remain powered up at minimum power for 3 minutes out of 8. This function can be helpful in very cold
countries.
L1
www.tecnoautomazione.com
Pag. 9 / 17