34
4
SYSTEMA S.p.A.
INFRA ES rev. 02GBEN13112018
INSTALLATION
For the models INFRA 6 ES (all the models), IN-
FRA 9 ES 45 and Infra 12 ES 45
- Fit the coupling (R) on the extractor by inserting
the relevant gasket (G) between the extractor and
coupling, being sure to position them as shown in
figure 4.11.
- Secure the burner to the end of the supply pipe
and fix the extractor to the return pipe (fig. 4.10).
Also refer to paragraph 3.5, 3.6 and 3.9 respec
-
tively on pages 17, 18 and 22.
- Make sure that the radiant circuit is correctly po
-
sitioned with the correct measurement to the pre
-
viously positioned brackets, as shown in fig. 4.7
on page 32.
For models:
- INFRA 9 ES 53;
- INFRA 9 ES 53 BL;
- INFRA 12 ES 60;
- INFRA 12 ES 60 BL;
- INFRA 15 ES 60.
- Secure the burner to the end of the supply pipe
and fix the extractor to the return pipe (fig. 4.12).
Also refer to paragraph 3.7, 3.10 and 3.12 re
-
spectively on pages 19, 23 and 25.
- Make sure that the radiant circuit is correctly po
-
sitioned with the correct measurement to the pre
-
viously positioned brackets, as shown in fig. 4.7
on page 32.
For all the models:
5) Fix the first bracket to the return pipe using the
bracket locking hook bolt supplied (fig. 4.13) so
that the supply pipe is free to expand.
Legend Figures 4.10, 4.11, 4.12
1= Burner
2= Supply pipe
3= Return pipe
4= Extractor
G= Gasket
R= Extractor coupling
Fig. 4.10
Fig. 4.12
Fig. 4.13