Copyright ©Synway All Rights Reserved122 / 132
V2.1.2
Below are the BRI protocols supported bySyn_PBX80 andSyn_PBX100:
NT_PTP
: BRI PTP Point to Point signaling (Network side)
NT_PTMP
: BRI PTMP Point to Multi-Point signaling (Network side)
TE_PTP
: BRI PTP Point to Point signaling (CPE side)
TE_PTMP
: BRI PTMP Point to Multi-Point signaling (CPE side)
Configure the protocols according to the telephony provider gave. Save and reboot the SYN_PBX
system, after rebooting you get red LED to indicate a successful BRI CPE connection, and green
LED to indicate a successful BRI NET connection.
On the web GUI
Operator
page you will see BRI connection status like below, but now all
connected.
Please note which ports are not connected and then power off the SYN_PBX system and unplug
the module to adjust the jumpers for the BRI ports according to the well-working ones.
8.2.4 MFC/R2 Settings
In the E1 settings section and Signaling field by selecting R2 you are able to configure E1 R2
signaling.
R2 parameter descriptions:
Variant
: Protocol variant setting depends on country and carries.
Max ANI
: The maximum expected number of ANI digits.
Max DNIS
: The expected number of dialed digits.
Get ANI First
: The usual behavior for incoming calls is to get the calling party category and
the ANI as soon as possible, and to get the DNIS afterwards. This doesn't work on all systems,
Содержание Syn_PBX100 U100