自動化產品
/Automation Products
–
70SB Laser Marking Machine Assembly Manual(Discontinued)
Troubleshooting Q&A
–
40
a.
b.
c.
d.
e.
f.
g.
h.
i.
j.
11
Troubleshooting Q&A
11.1
Galvanometer
Problem
Fi
gu
re
Possible
cause
Elimination methods
Start marking. No
action on the
galvanometer
-
1. Not
properly
powered up
2. Wiring
problem
3. Parameter
error
4.Controller
hardware
problem
1. Check whether
the +-15V power supply
has normal output.
2. Wiring problem
1. Check whether
the wire is properly
connected
2. Confirm whether
the standard 15pin wire
is used, and test if the
wire is abnormal using
the wire of the same
standard
3. Use an avometer
and other equipment to
confirm whether the
wire pins are properly
connected
3. Parameter error
1. Check whether
the Kp coefficient of the
galvanometer is correct
(the controller has no
such function)
2. Confirm R17008
(operation mode) =2
(transferring while
marking)
4. Controller
hardware problem
1. Confirm whether
R17111~R17113 output
the control signal in
Register, and if so, use
the electricity meter to
confirm whether the
corresponding pin
output the normal
voltage value
Содержание 70SB
Страница 1: ...70SB Laser Marking Machine Assembly Manual Discontinued 2022 05 05 2021 10 18...
Страница 16: ...Automation Products 70SB Laser Marking Machine Assembly Manual Discontinued System setup 16...
Страница 17: ...Automation Products 70SB Laser Marking Machine Assembly Manual Discontinued System setup 17...
Страница 25: ...Automation Products 70SB Laser Marking Machine Assembly Manual Discontinued Operation of marking 25...