getting started
28
SYNRAD OEM v40 Operator’s Manual Version 4
Connecting
In order for your Firestar v40 laser to properly operate, several input signals must be applied to the DB-15
User I/O connector before lasing is enabled. Remote Interlock (Pin 3) and Shutter Open Request (Pin
10) inputs must be powered before the laser will fire. In applications where Firestar is integrated into an
automated system and safety interlocks are required, these input signals must be provided by the customer’s
control system. The Quick Start Plug included in the ship kit has factory-installed shorting jumpers wired
into it to enable these inputs. Connect the Quick Start Plug to the User I/O connector when performing
initial start-up and testing of your Firestar laser.
For further information about the User I/O connector, see User I/O connections in the Technical Reference
chapter for User I/O pinouts and signal descriptions. See Integrating Firestar safety features, also in the Tech-
nical Reference chapter, for detailed instructions on integrating Firestar’s keyswitch, shutter, and remote
interlock functions with automated control systems. Figure 3-7, Quick Start Plug wiring diagram, also in the
Technical Reference chapter shows the Quick Start Plug wiring diagram.
Caution
possible
personal in-
jury
The Quick Start Plug is intended solely for initial start-up and testing
of the laser. Because this plug jumpers Remote Interlock and Shutter
Open Request signals, the laser will fire immediately on application
of a PWM Command signal. Your integrated control system should
provide interlock and shutter signals directly to the DB-15 User I/O
connector only after safe operating conditions are established.