maintenance/
troubleshooting
94
SYNRAD OEM v40 Operator’s Manual Version 4
Troubleshooting
Status LEDs
Firestar v40 LED indicators, also mirrored as output signals on the User I/O connector, provide status in-
formation to the user. Table below shows Firestar output signal and LED indicator states during normal
and fault conditions. User I/O outputs are Closed when the state indicated by the signal name is True.
Table 5-2
Status signals
LED Indicator
LED Status Signal Name
User I/O Output Status
Normal
Fault
Normal
Fault
INT
Green Red
Interlock Open Open Closed
TMP
Green Red
Over Temperature Open
Closed
RDY
Yellow Off
Laser Ready
Closed Open
SHT
Blue Off Shutter Open Closed Open
LASE
Red
Off
Laser Active
Closed Open
On v40 Keyswitch lasers, the RDY indicator illuminates yellow only when INT and TMP indicators are
green and the Keyswitch is cycled from OFF to the ON position. After the RDY indicator illuminates, a
five-second delay occurs before Firestar is permitted to lase. The SHT LED illuminates blue when a Shut-
ter Open Request signal is applied and the manual Shutter Switch is set to ON. If the RDY indicator is
lit and the shutter is switched from Closed to Open, there is a five-second delay until PWM inputs are
recognized. When PWM Command pulses are applied (and are long enough to produce laser output) the
LASE LED illuminates red.
On OEM lasers, the RDY lamp illuminates on DC power-up when INT and TMP indicators illuminate
green. After the RDY indicator illuminates, a five-second delay occurs before Firestar is permitted to lase.
The SHT LED illuminates blue when a Shutter Open Request signal is applied. If the RDY indicator is
lit and then a Shutter Open Request signal is applied, there is a five-second delay until PWM inputs are
recognized. When PWM Command pulses are applied (and are long enough to produce laser output) the
LASE LED illuminates red.
Note: Firestar
RDY and SHT indicators (as well as Laser Ready and Shutter Open outputs) denote
separate control functions. Although the RDY lamp may light while the SHT LED is Off (Shutter
Switch Closed or Shutter Open Request signal missing), no power is applied to the RF boards
until both RDY and SHT indicators are illuminated.
Following tables show how Firestar’s signal status changes when remote interlock, over temperature, or
shutter closed conditions occur.
Содержание Firestar V Series
Страница 29: ...getting started 29 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 85: ...technical reference 85 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 103: ...maintenance troubleshooting 103 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...