operation
46
SYNRAD OEM v40 Operator’s Manual Version 4
OEM controls and indicators
OEM v40 rear panel
Figure 3-4
OEM v40 rear panel controls and indicators
1
DC Power Cables – receives 30 VDC from the DC power supply. The red (positive) cable contains a
replaceable 25 A in-line fuse.
2
INT (Remote Interlock) Indicator – illuminates green to indicate that a remote interlock circuit is
closed and that lasing may be enabled. The INT indicator is red and lasing is disabled if the interlock
input is open.
3
TMP (Temperature) Indicator – illuminates green to indicate that laser temperature is within limits
and that lasing may be enabled. The TMP indicator is red and lasing is disabled if the laser’s tem-
perature rises above safe operating limits.
4
RDY (Ready) Indicator – illuminates yellow when the laser is enabled, indicating that, after a five-
second delay, lasing will begin when a PWM Command signal is applied.
5
SHT (Shutter) Indicator – illuminates blue to indicate that the Quick Start Plug or a Shutter Open
Request signal is connected to the User I/O port and lasing may be enabled. When a Shutter Open
Request signal is applied, there is a five-second delay until PWM inputs are recognized.
6
LASE Indicator – illuminates red to indicate that the laser is actively lasing. The LASE indicator is
off when tickle pulses are being generated and illuminates red when PWM Command signal pulses
are long enough to produce laser output.
7
USER I/O Connector – provides a connection point for auxiliary output power as well as input and
output signals. Refer to User I/O connections in the Technical Reference chapter for pinouts and
signal descriptions.
8
WATER IN Port (water-cooled only) – labeled IN, this connection provides the cooling water inlet
to Firestar’s water-cooling system.
9
WATER OUT Port (water-cooled only) – labeled OUT, this connection provides the cooling water
outlet from Firestar’s water-cooling system.
USER I/O
INT TMP RDY SHT LASE
(Water-Cooled v40 OEM Shown)
1
2
4
5
3
6
7
8
9
IN
OUT
Содержание Firestar V Series
Страница 29: ...getting started 29 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 85: ...technical reference 85 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 103: ...maintenance troubleshooting 103 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...