getting started
25
SYNRAD OEM v40 Operator’s Manual Version 4
Connecting
Electrical connections
The following procedures describe how to complete electrical connections to both Keyswitch and OEM
Firestar v40 lasers.
DC power supply
Firestar v40 lasers require a DC power supply that provides 30 VDC at 24 A maximum. We recommend
the SYNRAD DC-5 DC power supply that supplies 30 VDC at 33 A. AC input requirements for the DC-5
are 90–132 VAC (low range) or 175–264 VAC (high range), single phase (1ø), 15 A max, 47–440 Hz.
To connect the DC-5 power supply for 120 VAC (low range) input, refer to Figure 1-7 and follow the steps
listed in the 120 VAC input operation section. If you are connecting the DC-5 for 240 VAC (high range)
input, refer to Figure 1-7 and follow the steps listed in the 240 VAC input operation section.
Figure 1-7
DC-5 power supply
Note: The negative (–) side of the DC input to the laser is internally connected so that the laser chas-
sis serves as DC power ground. You should isolate the laser’s DC power supply so that the only
grounded connection is at the laser. Alternatively, you can mount the laser chassis on an insulat-
ing pad or film in order to electrically isolate the laser when other equipment is grounded to the
laser’s DC power supply.
Caution
possible
equipment
damage
Do not reverse polarity when connecting DC power cables to your
DC power source. Reversed DC polarity will damage the laser’s inter-
nal RF power supply. Carefully follow the directions below to ensure
that DC cable leads are properly connected to the correct DC output
terminals.
3
2
1
10
11
12
Input Section
Output Section
SYNRAD DC-5 DC Power Supply
1
2
3
4
5
6
1
2
3
4
5
6
VOLT
ADJ.
VOLT
ADJ.
+
_
1
2
3
4
5
6
VOLT
ADJ.
1
2
L
N
1
2
3
4
Содержание Firestar V Series
Страница 29: ...getting started 29 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 85: ...technical reference 85 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...
Страница 103: ...maintenance troubleshooting 103 SYNRAD OEM v40 Operator s Manual Version 4 This page intentionally left blank ...