technical reference
72
SYNRAD OEM v40 Operator’s Manual Version 4
User I/O connections
Sample I/O circuits
Sample inputs
Figure below illustrates one method of supplying a Remote Interlock signal using a customer-supplied
limit switch. Firestar’s +24 VDC Auxiliary Power output powers the circuit. Note that Pin 4, +5 VDC Auxil-
iary Power, could have been used instead, depending on circuit voltage requirements.
Figure 4-10
Customer-supplied interlock
Figure below shows another variation for supplying a Remote Interlock signal to the laser. In this case,
the customer is using a limit switch and supplying a negative voltage to drive Firestar’s input circuit.
(12)
AUX. DC POWER
GROUND
Close switch to
enable interlock
USER I/O PINS
(5)
+24 VDC AUXILIARY
POWER
(3)
REMOTE INTERLOCK
(11)
INPUT COMMON
Close switch to
enable interlock
USER I/O PINS
(3)
REMOTE INTERLOCK
(11)
INPUT COMMON
–12 VDC
0 VDC
Figure 4-11
Customer-supplied interlock, negative voltage
A Programmable Logic Controller (PLC) can also drive Firestar inputs. Figure below shows a typical
method for connecting to a PLC output module when only one Firestar input is used.
USER I/O PINS
(3)
REMOTE INTERLOCK
(11)
INPUT COMMON
PLC
DC
OUTPUT
MODULE
+V
(+5–24V)
Figure 4-12
PLC driven interlock signal