Connecting
Figure 1-11
Gas purge kit assembly
1
Locate the Gas Purge Kit in the i401 ship kit. The kit consists of two each male/female 90° quick-
disconnect fittings, a straight fitting, a low-flow gas filter, and a support bracket with fasteners.
2
Refer to Figure 1-11A and fasten the filter support bracket to the rear of the i401 laser using the
6–32 Allen capscrews and # 6 flat washers provided in the kit.
3
Assemble the two 90° fittings, straight fitting, and filter as shown in Figure 1-11B. Be sure to orient
the directional arrow on the filter as shown.
4
Loosen the two jam nuts on the straight fitting so it will slide into the support bracket.
5
Refer to Figure 1-11C and plug the filter assembly into the
Gas Purge
port connector.
6
Adjust the jam nuts on the on either side of the support bracket to hold the filter assembly in posi-
tion.