SY-7000 SDK Manual Terminal Configuration Instructions
15
2.0.7.2.5
IP Settings
This menu displays the wireless IP address settings in the current format:
IP=000.000.000.000
NM=000.000.000.000 Gateway=000.000.000.000
2.0.7.2.6
Wireless Status
The wireless status menu displays a live network of transmitting data, including errors over the wireless
network in the following format:
RX bytes: (bytes) Errors: (bytes)
TX bytes: (bytes) Errors: (bytes)
Link=% Signal=(Xlnt) Noise=-0dBm
(These options display the link and signal strength, as well as wireless noise. The signal is displayed as
“Xlnt” as it approaches closer to zero, which becomes a better connection.)
2.0.7.2.7
Wireless Mac Address
The wireless MAC address which applies to the wireless device network, displayed in the following
format:
00:00:00:00:00:00
2.0.8 Configure Access
The access configuration menu allows the terminal to be configured for what acceptable methods are
available for accessing the clock configuration menu. Note that if the badge length changes, so must the
access configuration. The default for entering the configuration menu is “00000”. If the badge length is
changed, the configuration code will change by either adding or removing a subsequent character.
Warning! If the access code is changed and later forgotten,
there is no way to retrieve it
.
The termi-
nal will need to be sent back to the factory for repair, and have the original programming
restored. When selecting an access code, select something and write it down to prevent being
locked out from the terminal.
Example:
Default code is “00000”
Code is changed to “12345”
Badge length is changed to 6 (in software)
By default, code is changed to “123450”
2.0.9 Utilities
This menu displays a variety of utilities available with the TA7000 series terminals.
2.0.9.1
Telnet Utilities
The Telnet utilities are used for enabling or disabling Telnet.
2.0.9.1.1
Enable Telnet
Enables the Telnet utility.
2.0.9.1.2
Disable Telnet
Disables the Telnet utility.
Содержание SY-7000 SDK
Страница 1: ...SY 7000 SDK Manual SYnel Industries LTD...
Страница 10: ...IntroductionSY 7000 SDK Manual 10 1 1 3 2Bottom connector panel...
Страница 33: ...Writing the SDK ApplicationSY 7000 SDK Manual 33...
Страница 37: ...Creating and Loading the Application File to the TerminalSY 7000 SDK Manual 37...
Страница 40: ...SY 7000 SDK Manual 40 Step 6 Use the default settings on this screen and click Next...
Страница 41: ...SY 7000 SDK Manual 41 Step 7 Specify the location to store the installation files and click Next...
Страница 42: ...SY 7000 SDK Manual 42 Step 8 Select Direct Connection and click Next...
Страница 44: ...SY 7000 SDK Manual 44 Step 10 Click the sign next to Devel to expand it...
Страница 45: ...SY 7000 SDK Manual 45 Step 11 Under Devel scroll down to gcc...
Страница 46: ...SY 7000 SDK Manual 46 Step 12 Select gcc by clicking on the word Skip once...
Страница 48: ...SY 7000 SDK Manual 48 Cygwin will now download and install the packages that you selected...
Страница 49: ...SY 7000 SDK Manual 49 Step 14 Leave the options checked and click Finish...
Страница 51: ...SY 7000 SDK Manual 51...
Страница 52: ...SY 7000 SDK Manual 52...
Страница 54: ...SY 7000 SDK Manual 45...