background image

 

 

23 

Finally, after the password was successfully stored, the user will be asked whether he wants to enable password 
locking, if it is not already enabled. 

 

By pressing [OK], password locking is enabled. Pressing [Cancel] closes the dialog and keeps password locking 
disabled, but the password is set anyway. 

To change the password, simply open the 

Set Password

 dialog again. It is not required to enter the current password 

before changing it. 

Enable/Disable Locking 

The menu entry 

Settings > User Input Locking > Enable/Disable Locking

 lets the user choose whether password 

locking is disabled or enabled.  

Password Locking 

If the user requests to enable password locking and a password has already been set, the user will be asked to enter 
the password before password locking is enabled. If the user requests to enable password locking when no password 
has been set up, the user will be prompted to enter and confirm a password, before password locking is enabled. 

Simple Locking 

Simple locking can be enabled whether a password has been set or not. When simple locking 
is used, the user will be asked to press [Cancel] three times within 3 seconds when 
attempting to unlock the device by pressing the [OK] button from the home screen. 

Lock User Input 

Once password locking has been enabled, the additional menu item Lock User Input will 
appear on the top level of the menu and under 

Home > Menu > Settings > User Input 

Locking

. If the user activates this menu item, he will be asked whether the device should be 

locked. [OK] will lock the device, [Cancel] will keep it unlocked. 

The device will also be locked when the screen saver becomes active or after a power cycle if password locking has 
been enabled. 

Device Information 

The following information about the device is available under 

Home > Menu > Device Settings > Device Information

Model 

The d

evice model is reported as “XND

-

4” for all variants of the XND

-4. 

Boot Software 

The full version number of the boot software. 

Firmware 

The full version number of the firmware. 

Hardware 

The hardware revision. 

MAC Address 

The 

MAC address of the node’s Ethernet interface

Содержание XND-4D

Страница 1: ...XND 4 4 Port Ethernet DMX Node User Manual...

Страница 2: ...UM_XND 4 D0 LEN V01 07 DRAFT DOCX 2020 09 22...

Страница 3: ...troduction 4 Unpacking 4 Safety Information 5 Device Overview 7 Settings and Menu 10 Status LEDs 25 Screen Saver 26 Firmware Updates 26 Web Interface 27 Technical Data 29 Ordering Information 31 Credi...

Страница 4: ...ata to your fixtures from a computer or even from a mobile device Many light controller programs for PC or Mac support Art Net output natively and with the help of XND 4 s DHCP capability you can even...

Страница 5: ...damaged defective or wet or if they show signs of overheating Do not expose the device to rain or moisture Do not operate the device if any cover or component is missing damaged or deformed Refer any...

Страница 6: ...6 Do not use the device in areas where it is exposed to direct sunlight Do not use the device in areas that are highly inflammable...

Страница 7: ...on rack and truss mountable models regular RJ45 socket on XND 4D 6 Port buttons 1 4 These push buttons are used to open the port menu of the corresponding port A port status LED showing status inform...

Страница 8: ...supplied with both overload and ground fault earth fault protection Important Only attach or remove a Neutrik powerCON connector while it is connected to the mains to apply or cut power in an emergenc...

Страница 9: ...ors with RJ45 connectors or 3 pole box header connectors XLR Connectors RJ45 Connectors Box Header Connectors Each port is individually optically isolated On the XND 4D a box header and a RJ45 connect...

Страница 10: ...By keeping the Cancel button pressed for at least two seconds you can always navigate to the Home Screen From the Home Screen the menu is launched by simply pushing the OK button The following notatio...

Страница 11: ...rt running in sACN mode the 16 bit sACN universe a number in the range of 1 to 63999 is displayed at the bottom of the screen The left most number corrseponds to the universe of port 1 The universe nu...

Страница 12: ...button All following settings can also be changed via web interface on the Network Settings Page as seen on page 28 DHCP Navigate to Home Menu Network DHCP in order to enable or disable DHCP Dynamic H...

Страница 13: ...tatic Settings IP Address is set to the primary Art Net IP address 2 X Y Z The values X Y and Z are computed from the device s MAC address Static Settings Netmask is set to 255 0 0 0 Set to Secondary...

Страница 14: ...obsolete independent universes functionality is that Art Net 4 support allows an Art Net 4 aware controller to properly understand and if supported by the controller configure the port address of eac...

Страница 15: ...nding Text To append or insert text move the cursor to the position where you want to add your text Then push the OK button and select a character to add Confirm your selection by pressing OK Repeat t...

Страница 16: ...linking cursor is shown below the currently editable digit Use the encoder to increase or decrease that digit Push the port button corresponding to the port that is being edited to change the digit th...

Страница 17: ...rom the network Input1 The port is configured as DMX input and sends data to the network Off The port is turned off A bullet point is shown next to the currently active setting Use the encoder wheel t...

Страница 18: ...the same port If more than two controllers send data for the same port the following rules take effect Art Net The first two appeared data streams are merged All following ones are discarded sACN The...

Страница 19: ...IP address multicast for sACN Every reachable device in the same subnet can receive the data Unicast DMX data applied to the input port is transmitted to a unicast IP address set by the user Only one...

Страница 20: ...e sACN no RDM o Same as sACN Art Net RDM disabled on all ports 1 2 Art Net 3 4 sACN o Art Net RDM is enabled on all ports o All ports are configured as outputs o Ports 1 and 2 are configured to Art Ne...

Страница 21: ...i are displayed as decimal numbers Hexadecimal Art Net net Art Net sub net Art Net or sACN universe and Art Net sub uni are presented as hexadecimal numbers with a trailing h e g F3h A bullet point is...

Страница 22: ...he device is locked the user will only be able to see the Home Screen see page 10 and the Ethernet Port Status Information see page 25 Since the menu is unavailable while the device is locked the Ethe...

Страница 23: ...s enabled Simple Locking Simple locking can be enabled whether a password has been set or not When simple locking is used the user will be asked to press Cancel three times within 3 seconds when attem...

Страница 24: ...RDM Disabled on all output ports1 Auto universe label Enabled2 Independent universes Disabled3 Art Net version Art Net 44 All outputs enabled DMX output mode all ports Relaxed5 Art Net universe outpu...

Страница 25: ...onds once every 0 2 seconds The DMX ports and the Ethernet port can be selected using the respective port push button Further the DMX ports can also be selected via the menu Home Menu Outputs Output 1...

Страница 26: ...n saver is enabled Once the display is turned off it can be turned on again by pushing any button or by turning the encoder wheel by one unit in any direction The screen saver can be enabled or disabl...

Страница 27: ...essfully No Update Not receiving any updates on this universe for the last 10 seconds Off The port is currently disabled through settings made by the user No DMX The port is not receiving transmitting...

Страница 28: ...view and make changes to any relevant device information Furthermore the factory defaults can be restored from here A detailed description of the device settings can be found on page 21 Firmware Upda...

Страница 29: ...29 Technical Data XND 4R XND 4B XND 4D...

Страница 30: ...1 4 sACN ANSI E1 31 sACN draft version v0 2 DMX ANSI E1 11 RDM ANSI E1 20 Electrical standard signal ports EIA 485 Dimensions Rack Mountable Models Depth 136 mm 5 35 in Width 482 6 mm 19 in Height 44...

Страница 31: ...t notice this list of conditions and the following disclaimer 2 Redistributions in binary form must reproduce the above copyright notice this list of conditions and the following disclaimer in the doc...

Страница 32: ...ers using Art Net I or Art Net II the Art Net net must be set to 0 The Art Net net sub net and universe can be combined to a 15 bit port address with values from 0 to 32767 as shown below Bit Digit 14...

Страница 33: ...ace Compatible Browsers The web interface was tested with following browsers Browser Version Chrome 80 0 3987 132 Firefox 73 0 1 Safari 13 1 Opera 67 0 3575 53 Edge 44 17763 831 0 Internet Explorer 11...

Страница 34: ...warranty of any kind either directly or indirectly and is subject to change without prior written notice Swisson its employees or appointed representatives will not be responsible for any damages to...

Отзывы: