12
Label
Port Mode Description
in, out
No DMX signal present.
in, out
A valid DMX signal is detected.
out
Port is outputting a look which has been received before, but no updates
have been received for at least 10 seconds
1
.
in
An error on the DMX signal appeared.
To show additional information about the selected port, there are status indicators for the presence of RDM on
output ports, as well as the merge mode and status on the upper right of the display. These status indicators are only
available with Art-Net 4 and sACN.
Indicator
Port Mode Description
out
Receiving signal from one source.
out
Receiving signal from two sources. Merger active.
out
Receiving signal from more than two sources. See section Merge Mode
in
Sending signal to broadcast or multicast address.
in
Sending signal to unicast Address. See section Input Settings.
Indicator
Port Mode Description
out
Art-Net RDM is enabled.
out
Merger mode is HTP. See section Merge Mode
out
Merger mode is LTP. See section Merge Mode
Network Settings
The network settings can be found under
Home > Menu > Network
or by double tapping the
Ethernet port button.
All following settings can also be changed via web interface on the Network Settings Page as
seen on page 28.
DHCP
Navigate to
Home > Menu > Network > DHCP
in order to enable or disable DHCP (Dynamic Host Configuration
Protocol). Choose
Enable
if you want to have your network configured by a DHCP server.
This would typically be the case if you connect the XND-4 to a home or office network.
A bullet point is shown next to the currently active setting. Use the encoder wheel to choose
the desired setting and confirm by pressing [OK] in order to change the setting.
Static Settings
All settings under
Home > Menu > Network > Static Settings
apply only if DHCP is disabled
and are ignored otherwise. From this menu, you can choose the IP address, the netmask and
the gateway address to be used when DHCP is disabled.
IP Address
Use this menu item
to configure the device’s IP address. When the IP
address configuration
dialog is opened, it will look just like the dialog depicted to the right. A box encircling the first
number indicates that the first number is selected. While the first number (byte) of the IP
address is selected, use the encoder wheel in order to choose the desired value for the first
byte of the address, then push [OK] to confirm your selection.
1
6 seconds for firmware version 0.93 and earlier
Содержание XND-4D
Страница 1: ...XND 4 4 Port Ethernet DMX Node User Manual...
Страница 2: ...UM_XND 4 D0 LEN V01 07 DRAFT DOCX 2020 09 22...
Страница 29: ...29 Technical Data XND 4R XND 4B XND 4D...