Installation
0705
TTPM3 Printer/Encoder–Technical Manual
11
With Swecoin power supplies, just connect the cable from the power supply to J5.
If you use another type of power supply unit, 24 V cables are available from Swecoin AB,
order No. 01370-000.
Should you make cables of your own, connect the voltages according to the following
illustration. Note that protective ground and minus output should
not
be interconnected in
the power supply. At the printer end of the cable, use an AMP Mate-N-Lok connector
housing and two contact-sockets:
Housing: AMP No. 350777-1
GND
+24 V
Socket: AMP No. 350689-1
Figure 5. Power connection
Mode
Idle
150 mA
Standard text printing
2 A average
Peak current
6 A
Table 1. Current consumption
NOTE! –
The 24 V ground, as well as the chassis of the printer, must be connected to
ground potential (safety ground).
After fastening the printer, proceed with the installation instructions for desktop printer on
page 6.