3-23 ENGINE CONTROL SYSTEM
LOW OIL PRESSURE CAUTION SYSTEM
CONDITION :
Immediate activation of system when the oil pressure switch turns “ON” due to an engine oil pressure drop
below 100 kPa ( 1.0 kg / cm
2
, 14 psi.).
ACTION :
Engine speed
Automatically reduced to approx. 3000 r/min by intermittent fuel injection signal if the
system is activated at 3000 r/min or higher.
Caution lamp
“ OIL ” lamp lights continuously.
“ REV-LIMIT ” lamp lights continuously during engine speed rev-limiter activation.
Caution buzzer Sounds in a series of long (1.5 sec.) beeps.
RESET :
Stop engine and check engine oil level. Refill engine oil to the correct level if below the low oil mark.
If the engine oil level is correct, the following causes may be considered:
• Improper oil viscosity.
• Malfunctioning oil pressure switch.
• Clogged oil strainer or oil filter.
• Worn oil pump relief valve.
• Oil leakage from the oil passage.
• Excessive wear / damage of oil pump
NOTE:
The low oil pressure caution system is reset when the oil pressure is restored to over 1.0kg/cm
2
with approx.
3000 r/min or less engine speed operation.
However, the engine must be stopped and checked immediately once the system is activated.
Содержание DF 40
Страница 1: ...99500 87J00 01E ...
Страница 108: ......
Страница 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Страница 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Страница 272: ... _ _ r ...
Страница 279: ......
Страница 367: ... ...
Страница 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...
Страница 405: ...Prepared by Marine Power Products Division 1 st Ed January 1999 Manual No 99501 87J00 01E Printed in Japan 36 ...