![Suzuki DF 40 Скачать руководство пользователя страница 194](http://html.mh-extra.com/html/suzuki/df-40/df-40_service-manual_1408856194.webp)
6-51 POWER UNIT
(6) Remove conrod and conrod cap from crank pin.
(7) Using scale on Plastigauge envelope, measure Plastigauge
width at its widest point.
Conrod big end oil clearance
Standard : 0.020 – 0.040 mm (0.0008 – 0.0016 in.)
Service limit : 0.065 mm (0.0026 in.)
If measurement exceeds service limit, replace conrod bearing.
CRANKSHAFT
Crankshaft runout
Using a dial gauge, measure runout at center journal.
09900-20606 : Dial gauge
09900-20701 : Magnetic stand
Crankshaft runout
Service limit : 0.04 mm (0.0016 in.)
If measurement exceeds service limit, replace crankshaft.
Crankshaft thrust play
Measure thrust play with crankshaft, thrust bearing, journal
bearing and crankcase/cylinder block assembled in a normal
manner.
Tighten crankcase bolts to specified torque.
Crankcase bolt :
8 mm
25 N . m (2.5 kg-m, 18.1 Ib.-ft.)
10 mm
53 N . m (5.3 kg-m, 38.3 Ib.-ft.)
Use a dial gauge to read displacement in axial (thrust) direc-
tion of crankshaft.
Crankshaft thrust play
Standard : 0.11 – 0.31 mm (0.0043 – 0.0122 in.)
Service limit : 0.35 mm (0.0138 in.)
z
@
Содержание DF 40
Страница 1: ...99500 87J00 01E ...
Страница 108: ......
Страница 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Страница 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Страница 272: ... _ _ r ...
Страница 279: ......
Страница 367: ... ...
Страница 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...
Страница 405: ...Prepared by Marine Power Products Division 1 st Ed January 1999 Manual No 99501 87J00 01E Printed in Japan 36 ...