![Suzuki DF 40 Скачать руководство пользователя страница 229](http://html.mh-extra.com/html/suzuki/df-40/df-40_service-manual_1408856229.webp)
8-19 POWER TRIM AND TILT
PRINCIPLES OF OPERATION
TRIM/TILT “UP” CIRCUIT
The electric motor is operating in a clockwise direction. Check valve
A
will open, allowing oil to flow from the
reservoir to the pump. Oil flow from the pump enters the spool valve, moving it to the left, opening the “down”
pressure main check valve and returning oil from the upper cylinder chamber (plus oil from the reservoir) to
the pump. Pressure built up by the pump will then open the “up” pressure main check valve and oil will enter
the lower cylinder chamber.
When trim motor stops, both the “DOWN” pressure main check valve and the “up” pressure main check valve
will close to retain tilt/trim position.
When full trim/tilt “up” position is attained, sustained operation of the “up” relay will have no effect, as pump oil
flow will be returned to the reservoir through the “up” relief valve.
Oil reservoir
Upper cylinder chamber
Tilt rod
Piston
PTT motor
Check valve
A
Gear pump
Spool valve
“DOWN” pressure main check valve
“UP” relief valve
“UP” pressure main check valve
Lower
cylinder
chamber
Содержание DF 40
Страница 1: ...99500 87J00 01E ...
Страница 108: ......
Страница 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Страница 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Страница 272: ... _ _ r ...
Страница 279: ......
Страница 367: ... ...
Страница 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...
Страница 405: ...Prepared by Marine Power Products Division 1 st Ed January 1999 Manual No 99501 87J00 01E Printed in Japan 36 ...