![Suzuki DF 40 Скачать руководство пользователя страница 116](http://html.mh-extra.com/html/suzuki/df-40/df-40_service-manual_1408856116.webp)
ELECTRICAL 4-10
STARTER MOTOR RELAY
Two methods can be used to test starter motor relay.
09930-99320 : Digital tester
Method 1
1. Disconnect all cables / lead wires from starter motor relay.
2. Measure resistance between relay wiring leads.
Tester range :
W
W
W
W
W
(Resistance)
Starter motor relay solenoid coil resistance :
3.5 – 5.1
W
W
W
W
W
If measurement exceeds specification, replace starter motor
relay.
Method 2
Connect the wiring leads of the relay to battery (12V) and check
relay operation.
Tester range : (Continuity)
1. Disconnect all cables / wires from starter motor relay.
2. Connect Yellow /Green wire to positive
+
terminal, and Black
wire to negative
-
terminal of battery.
When 12V applied : Continuity between relay
terminal
1
1
1
1
1
and
2
2
2
2
2
.
3. Disconnect wiring leads from battery.
No voltage applied : No continuity between
relay terminal
1
1
1
1
1
and
2
2
2
2
2
.
If out of specification, replace starter motor relay.
Tester probe connection
Red
+
+
+
+
+
Black
-
-
-
-
-
Yellow / Green
Black
z
B
Y/G
1
2
B
Y/G
+
-
12V Battery
t
r
Содержание DF 40
Страница 1: ...99500 87J00 01E ...
Страница 108: ......
Страница 149: ...POWER UNIT 6 6 Remove eight bolts and nut Lift up and remove power unit from engine holder ...
Страница 263: ...10 1 WIRE HOSE ROUTING WIRING DIAGRAM DF40T DF50T ...
Страница 272: ... _ _ r ...
Страница 279: ......
Страница 367: ... ...
Страница 369: ...99501 87J00 01E OUTBOARD MOTOR Printed in Japan TK ...
Страница 405: ...Prepared by Marine Power Products Division 1 st Ed January 1999 Manual No 99501 87J00 01E Printed in Japan 36 ...