IGNITION AND ELECTRICAL 3-5
INSPECTION
IGNITER
Measure the resistance in the igniter unit.
09930-99320: Digital tester
Tester range:
Ω
(Resistance)
1. Remove the spark plug cap from the high-tension cord.
2. Measure the resistance.
Primary coil resistance: 0.5 – 0.9
Ω
Secondary coil resistance: 10 – 16 k
Ω
If the measurement is out of the specification, replace the igniter
unit.
SPARK PLUG CAP
09930-99320: Digital tester
Tester range:
Ω
(Resistance)
Measure the spark plug cap resistance.
Spark plug cap resistance: 4 – 6 k
Ω
If the measurement is out of the specification, replace the spark
plug cap.
IGNITER TO FLYWHEEL MAGNETO AIR GAP
Measure the air gap of between the flywheel magneto and
igniter unit.
09900-20803: Thickness gauge
Air gap: 0.5 mm (0.02 in)
Tester probe connection
Probe
Other probe
Primary coil
Terminal
Core
Secondary coil
High-tension cord
Core
Primary coil
Secondary coil
Tester probe connection
Probe
Other probe
Cap end
Other cap end
Содержание DF 25
Страница 1: ...99500 97J00 01E Printed in Japan TK K6 9 9 5 0 0 9 7 J 0 0 0 1 E ...
Страница 54: ...FUEL SYSTEM 4 9 7 Remove the needle valve C from the float 8 Remove the main jet D 9 Remove the main nozzle E ...
Страница 87: ...POWER UNIT 6 21 17 Remove a screw S and the reed valve T ...
Страница 143: ...WIRE AND HOSE ROUTING 9 1 WIRE AND HOSE ROUTING CONTENTS 9 HOSE ROUTING 9 2 WIRE ROUTING 9 3 WIRING DIAGRAM 9 4 ...
Страница 147: ...Prepared by Service Department May 2006 Manual No 99500 97J00 01E Printed in Japan 148 ...
Страница 148: ...99500 97J00 01E Printed in Japan TK K6 9 9 5 0 0 9 7 J 0 0 0 1 E ...