6-38 POWER UNIT
THERMOSTAT
REMOVAL
1. Remove the recoil starter assy. (See page 5-2.)
2. Remove the four bolts
2
and the thermostat cover
1
.
3. Remove the thermostat
3
.
INSPECTION
If salt deposits, corrosion, wear or other damage is found, clean
or replace the thermostat.
Thermostat operation
Check the thermostat operating temperature as follows.
1. Insert a length of thread between the thermostat valve/body
and suspend the thermostat in a container filled with water.
2. Place the thermometer in the container and heat water.
Observe water temperature when the thermostat valve
opens and releases the thread.
Thermostat operating temperature:
Standard: 48 – 52 °C (118 – 126 °F)
INSTALLATION
Installation is reverse order of removal with special attention to
the following steps.
1. Install the thermostat
1
.
2. Apply sealant to both surfaces of thermostat cover gasket
(as shown with hatched lines).
99000-31120: SUZUKI SILICONE SEAL
3. Install the gasket
2
and the thermostat cover
3
to the cylin-
der block and secure with the four bolts
4
.
Thermometer
Heater
Thermostat cover gasket
Содержание DF 25
Страница 1: ...99500 97J00 01E Printed in Japan TK K6 9 9 5 0 0 9 7 J 0 0 0 1 E ...
Страница 54: ...FUEL SYSTEM 4 9 7 Remove the needle valve C from the float 8 Remove the main jet D 9 Remove the main nozzle E ...
Страница 87: ...POWER UNIT 6 21 17 Remove a screw S and the reed valve T ...
Страница 143: ...WIRE AND HOSE ROUTING 9 1 WIRE AND HOSE ROUTING CONTENTS 9 HOSE ROUTING 9 2 WIRE ROUTING 9 3 WIRING DIAGRAM 9 4 ...
Страница 147: ...Prepared by Service Department May 2006 Manual No 99500 97J00 01E Printed in Japan 148 ...
Страница 148: ...99500 97J00 01E Printed in Japan TK K6 9 9 5 0 0 9 7 J 0 0 0 1 E ...