6-4 Air 

Shrouds

Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC809 chassis air 

shroud does not require screws to set up. Two identical air shrouds are needed in 

the system, one for each node.

Note:

 the air shroud is intended for use with passive CPU heatsinks only. When 

using active heatsinks, you should remove the air shroud.

Installing the Air Shrouds (Figure 6-4)

Confi rm that all six fans are in place and working properly

1. 

Place the fi rst air shroud into the chassis. The air shroud sits behind the 

2. 

system fans. Each air shroud covers three fans. 

Install the second air shroud in the same manner as the fi rst.

3. 

Figure 6-3: Replacing a System Fan

5

6

Содержание SUPERSERVER 1026TT-IBQF

Страница 1: ...SUPER SUPERSERVER 1026TT TF SUPERSERVER 1026TT IBXF SUPERSERVER 1026TT IBQF USER S MANUAL Revision 1 0a...

Страница 2: ...ny such disputes Super Micro s total liability for all claims will not exceed the price paid for the hardware product FCC Statement This equipment has been tested and found to comply with the limits f...

Страница 3: ...main components included with the server system and describes the main features of the Super X8DTT F X8DTT IBXF X8DTT IBQF serverboard and the SC809TQ 1200B chassis Chapter 2 Server Installation This...

Страница 4: ...headers and jump ers Refer to this chapter when adding or removing processors or main memory and when reconfiguring the serverboard Chapter 6 Advanced Chassis Setup Refer to Chapter 6 for detailed in...

Страница 5: ...v Preface Notes...

Страница 6: ...Power 1 5 SATA Subsystem 1 5 Control Panel 1 5 Rear I O Panel 1 5 Cooling System 1 5 1 4 1U Twin System Notes 1 6 System Power 1 6 SATA Backplane Drives 1 6 1 5 Contacting Supermicro 1 7 Chapter 2 Ser...

Страница 7: ...2 Power 3 3 3 4 Drive Carrier LEDs 3 3 Chapter 4 System Safety 4 1 Electrical Safety Precautions 4 1 4 2 General Safety Precautions 4 2 4 3 ESD Precautions 4 3 4 4 Operating Precautions 4 4 Chapter 5...

Страница 8: ...1 Unpacking 6 1 6 2 Control Panel 6 2 6 3 System Fans 6 3 System Fan Failure 6 3 6 4 Air Shrouds 6 4 6 5 Drive Bay Installation Removal 6 5 Accessing the Drive Bays 6 5 6 6 Power Supply 6 7 Power Sup...

Страница 9: ...IBQF as listed below Four passive CPU heatsinks SNK P0037P One air shroud MCP 310 18008 0N SATA Accessories Eight SATA hard drive carriers MCP 220 00047 0B One internal SATA backplane BPN SAS 809TQ T...

Страница 10: ...1066 800 SDRAM See Chapter 5 Section 6 for more details on installing memory into the system and refer to our web site for updates to supported memory Serial ATA The South Bridge ICH10R of the chipse...

Страница 11: ...G200eW graphics chip which includes 8 MB of DDR2 memory Other Features Other onboard features that promote system health include voltage monitors auto switching voltage regulators chassis and CPU over...

Страница 12: ...1 2 DDR3 DIMM 2 2 DDR3 DIMM 1 1 1 DDR3 DIMM 2 2 2 DDR3 DIMM C C A A B B D D E E F F Port1 Port0 Ports Ports 3 4 7 8 9 10 PCI E x16 ICH10R Ports 2 1 Kawela RJ45 RJ45 ESI PE4 1 PE5 WBD BMC VGA VGA DDR...

Страница 13: ...panels associated with each node serverboard Each control panel has LEDs to indicate power on network activity hard disk drive activity and system overheat conditions Each control panel also includes...

Страница 14: ...the I2 C signals used for power supply monitoring are received by the primary serverboard only When viewed from the front of the chassis the serverboard on the left is referred to as the primary board...

Страница 15: ...per Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technical...

Страница 16: ...1 8 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Notes...

Страница 17: ...ion for the rack unit that will hold the 1026TT TF 1026TT IBXF 1026TT IBQF It should be situated in a clean dust free area that is well ventilated Avoid areas where heat electrical noise and electroma...

Страница 18: ...the rack In multiple rack installations the racks should be coupled together Always make sure the rack is stable before extending a component from the rack You should extend only one component at a ti...

Страница 19: ...a ture Tmra Reduced Airflow Equipment should be mounted into a rack so that the amount of airflow required for safe operation is not compromised Mechanical Loading Equipment should be mounted into a r...

Страница 20: ...he installation instructions that came with the rack unit you are using Note This rail will fit a rack between 26 and 33 5 deep Identifying the Sections of the Rack Rails You should have received two...

Страница 21: ...hin the rack Installing the Inner Rail Extensions Figure 2 2 Place the inner rail extensions B over the preattached inner rails A which 1 are attached to the side of the chassis Align the hooks of the...

Страница 22: ...Secure to the Front of the Rack Secure to the Rear of the Rack Figure 2 3 Assembling the Outer Rails Secure Outer Rails Together Installing the Server into a Rack Confirm that chassis includes the inn...

Страница 23: ...rmine how far the server will extend out the front of the rack Larger chassis should be positioned to balance the weight between front and back If a bezel is included on your server remove it Then at...

Страница 24: ...To remove the system from the rack completely depress the locking tabs in 5 the chassis rails push the right side tab down and the left side tab up to continue to pull the system out past the locked...

Страница 25: ...es please refer to Chapter 6 Checking the Airflow Airflow is provided by six sets of 4 cm PWM fans each set of fans consists 1 of two fans that are mounted back to back and an air shroud The system co...

Страница 26: ...2 10 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Figure 2 5 Accessing the Inside of the System Remove these screws Remove this screw Remove this screw 1 2 3 1 4...

Страница 27: ...ed to take Note that the server has two control panels one for each serverboard installed in the system This allows each serverboard to be controlled independently of the other 3 2 Control Panel Butto...

Страница 28: ...an overheat condition which may be caused by cables obstructing the airflow in the system or the ambient room temperature being too warm Check the routing of the cables and make sure all fans are pre...

Страница 29: ...een LED on the front of the drive carrier indi cates drive activity A connection to the hard drive backplane enables this LED to blink on and off when that particular drive is being accessed Red The r...

Страница 30: ...3 4 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Notes...

Страница 31: ...onnecting power you should first power down the system with the operating system first and then unplug the power cords of all the power supply units in the system When working around exposed electrica...

Страница 32: ...rom your body which are excellent metal conductors that can create short circuits and harm you if they come into contact with printed circuit boards or areas where power is present Serverboard Battery...

Страница 33: ...static bags until ready for use Touch a grounded metal object before removing the board from the antistatic bag Do not let components or PCBs come into contact with your clothing which may retain a ch...

Страница 34: ...this practice is not strictly followed Figure 4 1 Installing the Onboard Battery LITHIUM BATTERY BATTERY HOLDER Please handle used batteries carefully Do not damage the battery in any way a damaged b...

Страница 35: ...t to handle them very carefully see previous chapter To prevent the X8DTT F X8DTT IBXF X8DTT IBQF serverboard from bending keep one hand under the center of the board to support it when handling The f...

Страница 36: ...op cover from the chassis to gain full access to the inside of the 3 server If already installed in a rack grasp the two handles on either side and pull the unit straight out until the rails lock into...

Страница 37: ...ach connection listed should be made for both serverboards in the chassis SATA drive cables SATA0 SATA3 Control Panel cable JF1 Connecting Power Cables The X8DTT F X8DTT IBXF X8DTT IBQF has two 20 pin...

Страница 38: ...5 2 I O Ports NMI x Key 3 3V Front UID Button NIC1 LED Activity NIC2 LED Activity UID LED 3 3V Reset Button Power Button Ground x Key Power On LED HDD LED NIC1 LED Link NIC2 LED Link OH Fan Fail Pwr...

Страница 39: ...bent otherwise contact your retailer immediately Refer to the Supermicro web site for updates on CPU support When handling the processor avoid placing direct pressure on the label area of the fan Also...

Страница 40: ...avoid damaging the CPU or the socket With the CPU in the socket in 4 spect the four corners of the CPU to make sure that it sits level and is properly installed Once the CPU is securely seated 5 in th...

Страница 41: ...the heatsink on top of the 3 CPU so that the four mounting holes are aligned with those on the preinstalled heatsink reten tion mechanism Screw in two diagonal screws i e 4 the 1 and the 2 screws unti...

Страница 42: ...eatsink to loosen it from the CPU Do not use excessive force when wrig gling the heatsink Once the heatsink is loose 5 remove it from the CPU socket To reinstall the CPU and the 6 heatsink clean the s...

Страница 43: ...nt inserting it incorrectly Gently 2 press down on the DIMM module until it snaps into place in the slot see Figure 5 3 Repeat for all DIMMs See tables below and on following pages 3 CAUTION Exercise...

Страница 44: ...t from the slot Figure 5 3 DIMM Installation Top View of DDR3 Slot Release Tab Release Tab Note Notch should align with the receptive key point on the slot Notch Notch Front View DIMM Population Table...

Страница 45: ...sible System Memory Allocation Availability System Device Size Physical Memory Remaining Available 3 GB Total System Memory Physical Memory Remaining Available 4 GB Total System Memory Firmware Hub fl...

Страница 46: ...LE2 JNMI1 JSPK1 T SGPIO0 I SATA5 I SATA4 P2 DIMM3B P1 DIMM1A P2 DIMM3A P1 DIMM1B P2 DIMM2B P1 DIMM2A P2 DIMM2A P1 DIMM2B P2 DIMM1B P1 DIMM3A P1 DIMM3B VGA COM1 LAN2 LAN1 USB0 1 IPMI_LAN PCI E 2 0 x16...

Страница 47: ...C Header JF1 Front Panel Connector JNMI1 NMI Non Masked Interrupt Header JP10 Onboard 4 pin Power Connector JPSK1 Internal Speaker Buzzer Header JWR1 JWR2 12V 20 pin Power Connectors JWOL1 Wake On LA...

Страница 48: ...to the table on the right for the pin definitions Only one of the two ATX power connectors from each serverboard should be con nected to the power supply Reset Button Pin Definitions JF1 Pin Definiti...

Страница 49: ...inition 9 Vcc 10 Ground HDD LED Pin Definitions JF1 Pin Definition 13 UID Signal 3 3V 14 HDD Active NIC1 LAN1 LED The LED connections for LAN1 are on pins 11 and 12 of JF1 Attach LAN LED cables to dis...

Страница 50: ...the right for pin definitions NMI Button The non maskable interrupt button header is located on pins 19 and 20 of JF1 Refer to the table on the right for pin definitions NMI Button Pin Definitions JF...

Страница 51: ...he right for pin definitions SGPIO Header Pin Definitions T SGPIO 0 T SGPIO 1 Pin Definition Pin Definition 1 NC 2 NC 3 Ground 4 DATA Out 5 Load 6 Ground 7 Clock 8 NC I2 C Power Connector This header...

Страница 52: ...ich will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of CMOS To Clear CMOS First power down the system and unplug the po...

Страница 53: ...on the right for jumper settings The default setting is enabled LAN1 2 Enable Disable Jumper Settings JPL1 Jumper Setting Definition Pins 1 2 Enabled Pins 2 3 Disabled Red LED Overwrite Enable Disabl...

Страница 54: ...e Green flashing slowly ACPI S3 STR State Off Power off or power cable not connected Onboard Power LED LED2 There is an Onboard Power LED LE2 located near the VGA port When the green light is on or fl...

Страница 55: ...installing each item you must re boot the system before proceeding with the next item on the list The bottom icon with a CD on it allows you to view the entire contents of the CD 5 12 Installing Addi...

Страница 56: ...Supero Doctor III displays crucial system information such as CPU temperature system voltages and fan status See the Figure below for a display of the Supero Doctor III interface Notes The default Us...

Страница 57: ...vision 1 0 can be downloaded from our Web site at ftp ftp supermicro com utility Supero_Doctor_III You can also download SDIII User s Guide at http www supermicro com manuals other SDIII_User_Guide pd...

Страница 58: ...5 24 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Notes...

Страница 59: ...ly The following measures are generally sufficient to protect your equipment from ESD discharge Precautions Use a grounded wrist strap designed to prevent static discharge Touch a grounded metal objec...

Страница 60: ...ify the connection Connect the cable from JF1 on the serverboard to the control panel PCB printed circuit board Make sure the red wire plugs into pin 1 on both connectors Pull all excess cabling out o...

Страница 61: ...are hot swappable There is no need to power down the system when switching fans Changing a System Fan Figure 6 3 If necessary open the chassis while the power is running to determine which 1 fan has f...

Страница 62: ...h node Note the air shroud is intended for use with passive CPU heatsinks only When using active heatsinks you should remove the air shroud Installing the Air Shrouds Figure 6 4 Confirm that all six f...

Страница 63: ...t swap capability of the SATA drives Figure 6 4 Installing the Air Shrouds Use caution when working around the SATA backplane Do not touch the backplane with any metal objects and make sure no cables...

Страница 64: ...the screw holes of both line up Note that 2 there are holes in the carrier marked SATA to aid in correct installation Secure the drive to the carrier with four screws as illustrated below 3 Insert the...

Страница 65: ...nt units can be ordered directly from Supermicro see contact information in Chapter 1 Replacing the Power Supply Depress both main power buttons on the front of the chassis and then unplug the AC powe...

Страница 66: ...g the Power Supply Release Tab Pull the power supply out using the handle provided 4 Push the new power supply module into the power bay until it clicks into 5 place Plug the AC power cord back into t...

Страница 67: ...ns cannot be configured Options in blue can be configured by the user The right frame displays the key legend Above the key legend is an area reserved for a text message When an option is selected in...

Страница 68: ...ntial damages arising from a BIOS update If you have to update the BIOS do not shut down or reset the system while the BIOS is updating This is to avoid possible boot failure 7 2 Main Setup When you f...

Страница 69: ...d in your system CPU Type This item displays the type of CPU used in the motherboard Speed This item displays the speed of the CPU detected by the BIOS Physical Count This item displays the number of...

Страница 70: ...bootup screen options to be modified between POST mes sages or the OEM logo Select Disabled to display the POST messages Select Enabled to display the OEM logo instead of the normal POST messages The...

Страница 71: ...ds or longer The options are Instant_Off and 4_Second_Override Restore on AC Power Loss Use this feature to set the power state after a power outage Select Power Off for the system power to remain off...

Страница 72: ...hysical computer The options are Enabled and Disabled Note If there is any change to this setting you will need to power off and restart the system for the change to take effect Please refer to Intel...

Страница 73: ...e C3 C6 or C7 requests to C1 based on un core auto demote information The options are Disabled and Enabled C3 Auto Demotion When enabled the CPU will conditionally demote C6 or C7 requests to C3 based...

Страница 74: ...used to trigger fail over The spare memory is put online and used as active memory in place of the failed memory Demand Scrubbing A memory error correction scheme where the Processor writes corrected...

Страница 75: ...e defines how many meters above or below sea level the system is located The options are Sea Level or Below 1 300 301 600 601 900 901 1200 1201 1500 1501 1800 1801 2100 2101 2400 2401 2700 2701 3000 D...

Страница 76: ...user guide for the desired setting The options are 256 MB and 128MB XSouthBridge Configuration This feature allows the user to configure the settings for the Intel ICH South Bridge chipset USB Functio...

Страница 77: ...DE Master and Fourth IDE Master These settings allow the user to set the parameters of Primary IDE Master Slave Secondary IDE Master Slave Third and Fourth IDE Master slots Hit Enter to activate the f...

Страница 78: ...transfer rate of 5 2 MBs Select 2 to allow the AMI BIOS to use PIO mode 2 It has a data transfer rate of 8 3 MBs Select 3 to allow the AMI BIOS to use PIO mode 3 It has a data transfer rate of 11 1 MB...

Страница 79: ...isabled to prevent the AMI BIOS from using the S M A R T Select Enabled to allow the AMI BIOS to use the S M A R T to support hard drive disk The options are Disabled Enabled and Auto 32Bit Data Trans...

Страница 80: ...ly becomes unavailable Select 3F8 IRQ4 to allow the serial port to use 3F8 as its I O port address and IRQ 4 for the interrupt address The options for Serial Port1 are Disabled 3F8 IRQ4 3E8 IRQ4 2E8 I...

Страница 81: ...This feature allows the user to monitor system health and review the status of each item as displayed CPU Overheat Alarm This option allows the user to select the CPU OverheatAlarm setting which deter...

Страница 82: ...thermal conditions in the processor Low Medium and High This makes it easier for the user to understand the CPU s temperature status rather than by just simply seeing a temperature reading i e 25o C...

Страница 83: ...Disabled Full Speed 12V to disable the fan speed control function and allow the onboard fans to constantly run at the full speed 12V The Options are 1 Disabled Full Speed 2 Server Mode 3 Workstation...

Страница 84: ...e options are Enabled and Disabled XIPMI Configuration X8DTT F IBXF IBQF Only Intelligent Platform Management Interface IPMI is a set of common interfaces that IT administrators can use to monitor sys...

Страница 85: ...nt Dir Type Event Data Clear BMC System Event Log This feature is used to clear the BMC System Event Log Caution Any cleared information is unrecoverable Make absolutely sure that you no longer need a...

Страница 86: ...Number Channel Number Status This feature returns the channel status for the Channel Number selected above Channel Number is OK or Wrong Channel Number XIP Address Configuration Enter the IP address...

Страница 87: ...ion Enter the Mac address for this machine This should be in decimal and in dotted quad form i e 192 168 10 253 The value of each three digit number separated by dots should not exceed 255 as shown in...

Страница 88: ...EF interprets BMC events and performs actions based on pre determined settings or traps under IPMI 1 5 specifications For example powering the system down or sending an alert when a triggering event i...

Страница 89: ...tion for more informa tion at www intel com The options are Disabled and Enabled BMC Watch Dog Timer Action Allows the BMC to reset or power down the system if the operating system hangs or crashes Th...

Страница 90: ...r means such a password has not been used and Set means a user password has been entered for the system Change Supervisor Password Select this feature and press Enter to access the submenu and then ty...

Страница 91: ...IS displays a warning when any program or virus is sues a Disk Format command or attempts to write to the boot sector of the hard disk drive The options are Enabled and Disabled 7 5 Boot Configuration...

Страница 92: ...3rd Drive etc 1st Drive SATA XXXXXXXXX XRemovable Drives This feature allows the user to specify the boot sequence from available Removable Drives The settings are 1st boot device 2nd boot device and...

Страница 93: ...from the Exit menu and press Enter Discard Changes Select this option and press Enter to discard all the changes and return to the AMI BIOS Utility Program Load Optimal Defaults To set this feature s...

Страница 94: ...7 28 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Notes...

Страница 95: ...l not allow the system to continue the boot up procedure If a fatal error occurs you should consult with your system manufac turer for possible repairs A 1 BIOS Error Beep Codes BIOS Error Beep Codes...

Страница 96: ...A 2 SUPERSERVER 1026TT TF 1026TT IBXF 1026TT IBQF User s Manual Notes...

Страница 97: ...ys When the Windows XP 2003 Setup screen appears press S to specify ad 3 ditional device s Insert the driver diskette Intel AA RAID XP 2000 2003 Driver for ICH10R into 4 the floppy drive and press the...

Страница 98: ...n The Windows OS Setup screen will display 2 From the Windows XP 2003 Setup screen press the Enter key The 3 XP 2003 Setup will automatically load all device files and then continue with the Windows X...

Страница 99: ...384 or 96 GB for the system Note interleaved memory requires DIMMs to be installed in pairs refer to Section 5 6 for details Serial ATA Controller Intel ICH10R on chip controller to support six 3 Gb...

Страница 100: ...C 40 to 158 F Operating Relative Humidity 20 to 95 non condensing Non operating Relative Humidity 5 to 95 non condensing Regulatory Compliance Electromagnetic Emissions FCC Class A EN 55022 Class A EN...

Страница 101: ...C 3 Appendix C System Specifications Notes...

Страница 102: ...ailure to perform be reasonably expected to result in significant injury or loss of life or catastrophic property damage Accordingly Supermicro dis claims any and all liability and should buyer use or...

Отзывы: