6-4
S
UPER
S
ERVER 1026TT-TF/1026TT-IBXF/1026TT-IBQF User's Manual
6-4 Air
Shrouds
Air shrouds concentrate airfl ow to maximize fan effi ciency. The SC809 chassis air
shroud does not require screws to set up. Two identical air shrouds are needed in
the system, one for each node.
Note:
the air shroud is intended for use with passive CPU heatsinks only. When
using active heatsinks, you should remove the air shroud.
Installing the Air Shrouds (Figure 6-4)
Confi rm that all six fans are in place and working properly
1.
Place the fi rst air shroud into the chassis. The air shroud sits behind the
2.
system fans. Each air shroud covers three fans.
Install the second air shroud in the same manner as the fi rst.
3.
Figure 6-3: Replacing a System Fan
5
6