SUPERSERVER 5017R-iHDP User's Manual
2-5 Rack Mounting Instructions
This section provides information on installing the chassis into a rack unit with the
rails provided. There are a variety of rack units on the market, which may mean
that the assembly procedure will differ slightly from the instructions provided. You
should also refer to the installation instructions that came with the rack unit you are
using.
NOTE:
This rail will fit a rack between 26.5" and 36.4" deep.
Identifying the Inner Rail and Inner Rail Extension
The SC816LT chassis includes mounting rails for installing the system into a rack.
Each assembly consists of two sections: An inner rail which is pre-installed on the
chassis, an inner rail extension, and an outer rail that secures to the rack. These
assemblies are specifically designed for the left and right side of the chassis
Locking Tabs
Each inner rail has a locking tab. This tab locks the chassis into place when installed
and pushed fully into the rack. These tabs also lock the chassis in place when fully
extended from the rack. This prevents the server from coming completely out of
the rack when when the chassis is pulled out for servicing.
Figure 2-1. Identifying the Inner Rails and Inner Rail Extensions
Inner Rail
Inner Rail
Extension
Locking Tab
Three
Screws
Three
Screws
Содержание SC816LTS-655BP
Страница 1: ...SUPER SUPERSERVER 5017R iHDP Revision 1 0...
Страница 5: ...v Preface Notes...
Страница 10: ...Notes x SUPERSERVER 5017R iHDP User s Manual...
Страница 16: ...1 6 SUPERSERVER 5017R iHDP User s Manual Notes...
Страница 26: ...3 2 SUPERSERVER 5017R iHDP User s Manual Notes...
Страница 46: ...4 20 SUPERSERVER 5017R iHDP User s Manual Notes...
Страница 100: ...A 2 SUPERSERVER 5017R iHDP User s Manual Notes...
Страница 103: ...B 3 Appendix B System Specifications Notes...