Chapter 2: Server Installation
23
Installing the Chassis Rails
Begin the rack mounting procedure by installing the inner rails to the server chassis.
Installing the Inner Rails
1. Identify the left and right inner rails.
2.
Place the inner rail firmly against the side of the chassis, aligning the hooks on the side
of the chassis with the holes in the inner rail.
3. Slide the inner rail forward toward the front of the chassis until the rail clicks into the
locked position which secures the inner rail to the chassis.
4. Secure the inner rail to the chassis with the screws provided.
5. Repeat steps 1 through 4 above for the other inner rail.
Figure 2-4. Inner Rails Installed on the Chassis
Figure 2-3. Installing the Inner Rails
Inner Rails
4
4
3
2