background image

USER’S MANUAL 

Revision 1.0

A+ Server

®

AS -2014TP-HTR

Содержание A+ Server AS -2014TP-HTR

Страница 1: ...USER S MANUAL Revision 1 0 A Server AS 2014TP HTR...

Страница 2: ...ful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the ma...

Страница 3: ...o work properly please follow the links below to download all necessary drivers utilities and the user s manual for your server Supermicro product manuals http www supermicro com support manuals Produ...

Страница 4: ...yout 15 Quick Reference Table 16 Chapter 2 Server Installation 2 1 Overview 18 2 2 Preparing for Setup 18 Choosing a Setup Location 18 Rack Precautions 18 Server Precautions 19 Rack Mounting Considera...

Страница 5: ...MM Installation 38 DIMM Removal 38 PCI Expansion Card Installation 39 Motherboard Battery 40 3 4 Chassis Components 41 Hard Drives 41 Hard Drive Carrier Indicators 44 System Cooling 45 Optional Fan Co...

Страница 6: ...SuperDoctor 5 69 5 4 IPMI 69 Chapter 6 UEFI BIOS 6 1 Introduction 70 Starting the Setup Utility 70 6 2 Main Setup 71 6 3 Advanced 73 6 4 IPMI 88 6 5 Event Logs 91 6 6 Security 93 6 7 Boot 94 6 8 Save...

Страница 7: ...Super Micro Computer B V Het Sterrenbeeld 28 5215 ML s Hertogenbosch The Netherlands Tel 31 0 73 6400390 Fax 31 0 73 6416525 Email sales supermicro nl General Information support supermicro nl Technic...

Страница 8: ...Hot swap 3 5 HDD trays MCP 220 00075 0B 12 1U Right Hand Side riser cards RSC PR 6 X2 4 1U Left Hand Side riser cards RSC P 6 X2 4 Rackmount rail kit MCP 290 00053 0N 1 2000W Titanium Level redundant...

Страница 9: ...4 3200 MHz speed RDIMM LRDIMM 3DS NVDIMM memory in eight slots Expansion Slots per node Two PCI E 4 0 x16 low profile 6 6 long slots Storage per node Four hybrid M 2 slots in the 2280 and 22110 form f...

Страница 10: ...er nodes on the inner chassis wall This guide pin also acts as a stop when a node is fully installed If too much force is used when inserting a node this pin may break off Take care to slowly slide a...

Страница 11: ...des Each control panel on the A Server AS 2014TP HTR provides you with system monitoring and control for one server node LEDs indicate system power HDD activity network activity system overheat and po...

Страница 12: ...atus shown by this LED 4 UID Button The UID button is used to turn on or off the blue light function of the LED This light is displayed in the front as part of the UID button and with a separate LED a...

Страница 13: ...ded on the front of the chassis Front Chassis Features Item Feature Description 1 Control Panels per node Four control panels are provided on the chassis front for each node in the system 2 Drive Bays...

Страница 14: ...assis Rear Chassis Features Item Feature Description 1 Power Supplies Two redundant power supplies are accessible through the rear of the chassis 2 I O Ports Rear I O ports for each node are accessibl...

Страница 15: ...1 JUSB1 FB1 FAN4 FAN3 LED7 LED6 LED5 LED8 LED1 LED2 R429 R428 R418 R425 R420 MH1 MH4 MH7 MH2 FAN4 JF1 M 2 HC2 SATA24 27 CPU PCI E 4 0X4 SXB3 SXB2 SXB1 PWROK UID BMC CPU PCI E 4 0X4 M 2 HC4 SATA34 37 M...

Страница 16: ...Onboard CMOS battery COM 1 Front panel COM port 1 FAN 3 4 System fan headers IPMI_LAN Dedicated IPMI LAN port JF1 Front control panel JTPM1 Trusted Platform Module TPM Port 80 connector SIOM PCI E 4...

Страница 17: ...on Figure 1 5 System Block Diagram Note This is a general block diagram and may not exactly represent the features on your motherboard See the System Specifications appendix for the actual specificati...

Страница 18: ...Please read this section in its entirety before you begin the installation Choosing a Setup Location The system should be situated in a clean dust free area that is well ventilated Avoid areas where...

Страница 19: ...from power surges and voltage spikes and to keep your system operating in case of a power failure Allow any drives and power supply modules to cool before touching them When not servicing always keep...

Страница 20: ...ention should be given to power supply connections other than the direct connections to the branch circuit i e the use of power strips etc To prevent bodily injury when mounting or servicing this unit...

Страница 21: ...e 2 3 Installing the Rails The chassis package includes two rail assemblies in the rack mounting kit Each assembly consists of three sections an inner chassis rail an outer rail and a middle see Figur...

Страница 22: ...he chassis is pulled out for servicing Releasing the Inner Rail Use the procedure below to release the inner rails from the outer rails Releasing Inner Rail from the Outer Rails 1 Identify the left an...

Страница 23: ...chassis aligning the hooks on the side of the chassis with the holes in the inner rail 3 Slide the inner rail forward toward the front of the chassis until the rail clicks into the locked position wh...

Страница 24: ...onto the slots on the front of the rack If necessary use screws to secure the outer rails to the rack as illustrated above 4 Pull out the rear of the outer rail adjusting the length until it fits wit...

Страница 25: ...ont of the outer rail and make sure that the ball bearing shuttle is at the front locking position of the middle rail 4 Align the chassis inner rails with the front of the middle rails 5 Slide the inn...

Страница 26: ...emoved from the system 1 Use the operating system to power down the system 2 After the system has completely shut down disconnect the AC power cords from the power strip or outlet 3 Disconnect the pow...

Страница 27: ...27 Chapter 3 Maintenance and Component Installation Figure 3 1 Removing the Chassis Cover Remove two screws 1 2...

Страница 28: ...components Make sure that you install the processor into the CPU socket before you install the CPU heatsink If you buy a CPU separately make sure that you use an Supermicro certified heatsink only Ma...

Страница 29: ...crews holding down the force frame in the sequence of 3 2 1 The screws are numbered on the force frame next to each screw hole 2 The spring loaded force frame will rise up after the last screw securin...

Страница 30: ...the rail frame lift it to a position so you can do the next step of removing the external cap Note The rail frame is spring loaded so keep a secure grip on it as you lift it so it does not snap up 4 R...

Страница 31: ...e socket in one direction with the handle at the top Make sure that it is properly inserted into the CPU socket before closing the rail frame plate If it doesn t close properly do not force it as it m...

Страница 32: ...ace DO NOT force it into place 9 Gently lower the force frame down onto the rail frame and hold it in place until it is seated in the socket housing Note that the force frame is spring loaded and has...

Страница 33: ...steps When finished the force frame will be secured over both the rail frame and the CPU package 11 After the force frame is secured and the CPU package is in place now you must install the heatsink...

Страница 34: ...screws down on the heatsink in a clockwise fashion till it is secure The heatsink will now be secured and you have finished installing the processor and heatsink onto the motherboard Repeat this proce...

Страница 35: ...he rail frame is spring loaded so be careful lifting it up into a vertical position 5 Grip the handle of the carrier frame and pull upwards to extract it from the rail frame Return the carrier frame C...

Страница 36: ...ng Memory Modules Channel CPU D1 C1 B1 A1 CPU Socket SP3 E1 F1 G1 H1 1 DIMM Not Recommended CPU V 2 DIMMs Not Recommended CPU V V 4 DIMMs Not Recommended CPU V V V V 8 DIMMs CPU V V V V V V V V Popula...

Страница 37: ...T1 JDBG2 JVRM1 JUART2 JUART1 JDBG1 JWD1 UM7 UM5 MH8 MH12 MH16 MH20 MH9 MH13 MH17 MH21 MH10 MH14 MH18 MH22 MH11 MH15 MH19 MH23 MH25 J1 J2 J3 PC3 SATA7 SATA6 JVGA1 JUIDB1 JTPM1 JSD1 JSD2 JLAN1 JSIOM1 JC...

Страница 38: ...utwards on both ends of the DIMM slot to unlock it Side Notches Release Tabs 3 Identify the notches on the side and bottom of the DIMM module 4 Align the bottom notch on the DIMM module with the recep...

Страница 39: ...to install add on cards to the riser cards Begin by removing power from the system as described in Section 3 1 1 Remove the node from the chassis by pulling on the pulling ears 2 Remove the screw at t...

Страница 40: ...itive side facing up Then push the other side down until the clamp snaps over it Note Handle used batteries carefully Do not damage the battery in any way a damaged battery may release hazardous mater...

Страница 41: ...7HQ chassis contains four individual serverboards in separate node drawers Figure 3 5 Each serverboard node controls a set of three hard drives Note that if a serverboard node drawer is pulled out of...

Страница 42: ...handle 2 Use the handle to pull the drive out of the chassis The drives are mounted in drive carriers to simplify their installation and removal from the chassis Figure 3 7 and Figure 3 8 These carrie...

Страница 43: ...nt Installation 1 Figure 3 7 Chassis Drive Tray Figure 3 8 Removing Dummy Drive from Tray Drive Tray Dummy Drive Caution Except for short periods of time while swapping hard drives do not operate the...

Страница 44: ...se the drive tray handle Figure 3 9 Installing the Hard Drive Drive Tray Hard Drive 2 2 Note Enterprise level hard disk drives are recommended for use in Supermicro chassis and servers For information...

Страница 45: ...verboard node in the chassis is connected to the backplane through the adapter card mounted in the serverboard drawer In the event that one of the serverboard drawers is removed then the remaining ser...

Страница 46: ...n s power cord from the backplane 3 Lift the fan housing up and out of the chassis 4 Push the fan up from the bottom and out of the top of the housing 5 Place the replacement fan into the vacant space...

Страница 47: ...47 Chapter 3 Maintenance and Component Installation Figure 3 11 Replacing a System Fan...

Страница 48: ...Lay the chassis on a flat stable surface and remove the motherboard drawer from the chassis 1 Make sure that the motherboard expansion card if applicable and all components are properly installed in e...

Страница 49: ...replaced installation requires only a Phillips head screwdriver Adapter Card Removing the Adapter Card 1 Remove power from the system as described in Section 3 1 2 Remove the motherboard drawer from t...

Страница 50: ...expansion slot 2 Align the holes in the adapter card with the holes in the motherboard drawer 3 Secure the adapter card to the motherboard drawer using the five screws which were previously set aside...

Страница 51: ...by an Intel X550 controller AOC MTG b2TM two RJ45 10GbE ports supported by a Broadcom BCM57416 controller AOC MH25G b2S2GM two SFP28 25GbE ports supported by a Broadcom BCM57414 controler two RJ45 1Gb...

Страница 52: ...Figure 3 14 3 Remove the screw holding the SIOM shield on the pulling bracket See Figure 3 15 Install the correct I O shield See Figure 3 16 4 Remove the two screws holding the SIOM module and carefu...

Страница 53: ...53 Chapter 3 Maintenance and Component Installation Figure 3 15 Removing the SIOM Shield from the Pulling Bracket Inner View Figure 3 16 Installing SIOM Shield Inner View...

Страница 54: ...A Server AS 2014TP HTR User s Manual 54 Figure 3 18 Replace the Pulling Bracket Figure 3 17 Insert the SIOM into the Motherboard Drawer...

Страница 55: ...upply unit needs to be replaced one power supply can be removed without powering down the system Replacement units can be ordered directly from Supermicro see the contact information in the Preface of...

Страница 56: ...or removing components 4 1 Headers and Connectors SATA Ports The H12SST PS has six available SATA 3 0 ports SATA0 5 via a backplane supported by CPU The yellow SATA6 and SATA7 connectors support Supe...

Страница 57: ...he hard drive is not installed in the system Please go to the following link for more information on TPM http www supermicro com manuals other TPM pdf Trusted Platform Module Header Pin Definitions Pi...

Страница 58: ...g Expansion Slots The H12SST PS motherboard features several expansion slots These slots are supported by riser cards that are included with the system The table below describes their functions Expans...

Страница 59: ...16 SATA7 TPM PORT80 JSD1 2 SATA DOM POWER CPU PCI E 4 0 X16 BMC DIMMC1 DIMMD1 DIMMA1 DIMMB1 CPU UID SW COM1 VGA USB1 2 3 0 SIOM CPU PCI E 4 0 X16 X1 SXB4 CPU SLOT2 PCI E 4 0 X16 DIMMF1 DIMME1 DIMMH1 D...

Страница 60: ...rear UID LED is located next to the UID switch When you press the UID switch both rear and front UID LED indicators will turn on Press the UID switch again to turn off the LED indicators The UID Indic...

Страница 61: ...been completely removed CMOS Clear JBT1 is used to clear CMOS which will also clear any passwords Instead of pins this jumper consists of contact pads to prevent accidentally clearing the contents of...

Страница 62: ...must also be enabled in the BIOS The default setting is Reset Note When the Watch Dog is enabled the user needs to write their own application software to disable it Watch Dog Jumper Settings Jumper S...

Страница 63: ...MC Normal Fast Blinking BMC Initializing UID Switch and LED Indicator The rear UID LED2 is located next to the UID switch The front UID LED is located on the front panel When you press the UID switch...

Страница 64: ...n and all the system power rails are ready When the system is turned off or any one of the system power rails fails this LED will turn off Turn off the system and unplug the power cord before removing...

Страница 65: ...6 A PCI E 4 0 x16 slot is located at SXB2 Refer to the layout in Chapter 1 for the location Powered SATA DOM SuperDOM A SATA DOM Device on Disk is located at SATA6 7 on the motherboard SATA6 7 are use...

Страница 66: ...upermicro web page for your motherboard and click on Download the Latest Drivers and Utilities select the proper driver and copy it to a USB flash drive 3 Boot from a bootable device with the Windows...

Страница 67: ...ated then choose the storage drive on which you want to install it Figure 5 2 Load Driver Link 5 Once all devices are specified continue with the installation 6 After the Windows OS installation has c...

Страница 68: ...option is to go to the Supermicro website at http www supermicro com products Find the product page for your motherboard and Download the Latest Drivers and Utilities Insert the flash drive or disk an...

Страница 69: ...nagement Server SSM Server you can remotely control power on off and reset chassis intrusion for multiple systems with SuperDoctor 5 or IPMI SuperDoctor 5 Management Server monitors HTTP FTP and SMTP...

Страница 70: ...F1 F2 etc Each main BIOS menu option is described in this manual The Main BIOS screen has two main frames The left frame displays all the options that can be configured Grayed out options cannot be c...

Страница 71: ...time Highlight System Date or System Time using the arrow keys Enter new values using the keyboard Press Tab or the arrow keys to move between fields The date must be entered in MM DD YYYY format The...

Страница 72: ...Server AS 2014TP HTR User s Manual 72 CPLD Version This item displays the version of the CPLD firmware used in the system Total Memory This item displays the total size of memory available in the syst...

Страница 73: ...ubmenu items Boot Feature Quiet Boot Use this feature to select the screen display between the POST messages and the OEM logo upon bootup Select Disabled to display the POST messages Select Enabled to...

Страница 74: ...omatically reboot the system from a specified boot device after its initial boot failure The options are Disabled Legacy Boot and EFI Boot Power Configuration Watch Dog Function If enabled the Watch D...

Страница 75: ...evel 2 Updateable PSP Bootloader Version SMU FW Version ABL Version APCB Version APOB Version APPB Version ACPI Settings High Precision Event Tmber The options are Disabled and Enabled NUMA nodes per...

Страница 76: ...by the user The options are Disabled and Enabled If the item above set to Enabled the following items will become available for user s configuration Console Redirection Settings Terminal Type This fea...

Страница 77: ...elect 2 Stop Bits if slower devices are used The options are 1 and 2 Flow Control Use this feature to set the flow control for Console Redirection to prevent data loss caused by buffer overflow Send a...

Страница 78: ...400 57600 and 115200 bits per second Data Bits Use this feature to set the data transmission size for Console Redirection The options are 7 and 8 Parity A parity bit can be sent along with regular dat...

Страница 79: ...ion Legacy Console Redirection Settings Redirection COM Port For this setting select a COM port to display redirection of Legacy OS and Legacy OPROM messages The options are COM1 and SOL Resolution Fo...

Страница 80: ...ent computer A lower transmission speed may be required for long and busy lines The options are 9600 19200 57600 and 115200 bits per second Flow Control Use this item to set the flow control for Conso...

Страница 81: ...ontrol This sets the number of cores to be used by your system Once this option has been used to remove any cores a power cycle is required in order for the future selections to take effect Options in...

Страница 82: ...led and Auto ACS Enable Use this setting to enable disable ACS Options include Enabled Disabled and Auto Memory Configuration Memory Clock This setting allows you to select different memory clock spee...

Страница 83: ...he system supports 64 bit PCI decoding The options are Disabled and Enabled SR IOV Support If the system has SR IOV capable PCI E devices this setting will enable or disable the Single Root IO Virtual...

Страница 84: ...r Defined Firmware and AMI Native Support M 2 AHCI Firmware Source Use this setting to select between the AMI Native firmware support or the device vendor defined firmware support The options are Vend...

Страница 85: ...ystem The options are Disabled and PXE USB Configuration USB Configuration USB Module Version USB Controllers USB Devices Legacy USB Support Select Enabled to support onboard legacy USB devices Select...

Страница 86: ...sables the onboard SATA controller s hot plug feature PCH The options include Disabled and Enabled SATA Information This item displays information on the detected SATA devices connected and are detect...

Страница 87: ...empt Order TLS Authenticate Configuration This submenu allows the user to configure Transport Layer Security TLS settings Server CA Configuration Enroll Certification Enroll Certification using File U...

Страница 88: ...atform Management Interface IPMI settings BMC Firmware Revision This item indicates the IPMI firmware revision used in your system IPMI Status This item indicates the status of the IPMI firmware insta...

Страница 89: ...MAC address changes at the next system boot The options are No and Yes Configure IPV4 Support This section displays static configuration features for IPV4 support IPMI LAN Selection This item display...

Страница 90: ...on displays configuration features for IPV6 support IPV6 Support Use this feature to enable IPV6 support The options are Enabled and Disabled Configuration Address Source This feature allows the user...

Страница 91: ...BIOS Event settings Enabling Disabling Options SMBIOS Event Log Select Enabled to enable SMBIOS System Management BIOS Event Logging during system boot The options are Disabled and Enabled Erasing Set...

Страница 92: ...abled MECI Multiple Event Count Increment Enter the increment value for the multiple event counter Enter a number between 1 to 255 The default setting is 1 METW Multiple Event Count Time Window This i...

Страница 93: ...te a new or change an existing Administrator password Note that if the Administrator Password is erased the User Password will be cleared as well Password Check Select Setup for the system to check fo...

Страница 94: ...EFI OS after the boot failed from the legacy boot order The options include Disabled and Enabled FIXED BOOT ORDER Priorities Section This option prioritizes the order of bootable devices that the sys...

Страница 95: ...s include Select one to Delete UEFI Built in EFI Shell and Windows Boot Manager SATA SSD UEFI Application Boot Priorities Use this feature to specify which UEFI devices are boot devices Boot Order 1 H...

Страница 96: ...and reboot the computer Select Discard Changes and Exit from the Exit menu and press Enter Save Changes and Reset Select this option to reset the system after saving the changes Save Changes After com...

Страница 97: ...as User Defaults from the Exit menu and press Enter This enables the user to save any changes to the BIOS setup for future use Restore User Defaults To set this feature select Restore User Defaults f...

Страница 98: ...block and a main BIOS block a main BIOS image The boot block contains critical BIOS codes including memory detection and recovery codes for the user to flash a new BIOS image if the original main BIO...

Страница 99: ...e volumes of folders and files stored in the device To perform UEFI BIOS recovery using a USB attached device follow the instructions below 1 Using a different machine copy the Super ROM binary image...

Страница 100: ...screen or a similar screen below otherwise it will trigger a system reboot 4 After locating the new BIOS binary image the system will enter the BIOS Recovery menu as shown below Note At this point you...

Страница 101: ...erent system extract the BIOS package into a USB flash drive Proceed with flash update and press the Enter key You will see the BIOS recovery progress as shown in the screen below Note Do not interrup...

Страница 102: ...the directory that contains the BIOS package you extracted earlier from Step 7 Enter flash nsh BIOSname at the prompt to start the BIOS update process Note Do not interrupt this process until the BIOS...

Страница 103: ...nt for assistance Only certified technicians should attempt to install or configure components Read this appendix in its entirety before installing or configuring components in the Supermicro chassis...

Страница 104: ...considere los riesgos de la corriente el ctrica y familiar cese con los procedimientos est ndar de prevenci n de accidentes Al final de cada advertencia encontrar el n mero que le ayudar a encontrar e...

Страница 105: ...erken dient u zich bewust te zijn van de bij een elektrische installatie betrokken risico s en dient u op de hoogte te zijn van de standaard procedures om ongelukken te voorkomen Gebruik de nummers aa...

Страница 106: ...taci n Attention Avant de brancher le syst me sur la source d alimentation consulter les directives d installation Circuit Breaker Waarschuwing Raadpleeg de installatie instructies voordat u het syste...

Страница 107: ...ientes del edificio Aseg rese de que el dispositivo de protecci n no sea superior a 250 V 20 A Attention Pour ce qui est de la protection contre les courts circuits surtension ce produit d pend de l i...

Страница 108: ...gungsteilmodulen entfernt wird bevor es auf den Chassisinnenraum zur ckgreift um Systemsbestandteile anzubringen oder zu entfernen Advertencia El sistema debe ser disconnected de todas las fuentes de...

Страница 109: ...mkabels aangesloten op de voeding en van de behuizing te verwijderen Equipment Installation Warning Only trained and qualified personnel should be allowed to install replace or service this equipment...

Страница 110: ...tion Il est vivement recommand de confier l installation le remplacement et la maintenance de ces quipements des personnels qualifi s et exp riment s Warning This unit is intended for installation in...

Страница 111: ...so a una de estas reas mediante la utilizaci n de una herramienta especial cerradura con llave u otro medio de seguridad Attention Cet appareil doit tre install e dans des zones d acc s r serv s L acc...

Страница 112: ...lable ou quivalent recommand e par le fabricant Jeter les piles usag es conform ment aux instructions du fabricant Advertencia Existe peligro de explosi n si la bater a se reemplaza de manera incorrec...

Страница 113: ...nt aanbevolen wordt Gebruikte batterijen dienen overeenkomstig fabrieksvoorschriften afgevoerd te worden Redundant Power Supplies Warning This unit might have more than one power supply connection All...

Страница 114: ...oos te maken Advertencia Puede que esta unidad tenga m s de una conexi n para fuentes de alimentaci n Para cortar por completo el suministro de energ a deben desconectarse todas las conexiones Attenti...

Страница 115: ...Advertencia Cuando el sistema est en funcionamiento el voltaje del plano trasero es peligroso Tenga cuidado cuando lo revise Attention Lorsque le syst me est en fonctionnement des tensions lectriques...

Страница 116: ...plir con las normas de electricidad locales y nacionales Backplane Waarschuwing Een gevaarlijke spanning of energie is aanwezig op de backplane wanneer het systeem in gebruik is Voorzichtigheid is geb...

Страница 117: ...onale elektriciteitsvoorschriften Warnung Die Entsorgung dieses Produkts sollte gem allen Bestimmungen und Gesetzen des Landes erfolgen Warning Ultimate disposal of this product should be handled acco...

Страница 118: ...cyclage de ce produit sont g n ralement soumis des lois et ou directives de respect de l environnement Renseignez vous aupr s de l organisme comp tent Hot Swap Fan Warning Warning Hazardous moving par...

Страница 119: ...destornilladores y todos los objetos lejos de las aberturas del ventilador Attention Pieces mobiles dangereuses Se tenir a l ecart des lames du ventilateur Il est possible que les ventilateurs soient...

Страница 120: ...oder CAS zertifizierten Kabeln mit UL CSA gekennzeichnet an Ger ten oder Produkten die nicht mit Supermicro gekennzeichnet sind AC AC UL CSA UL CSE Supermicro Supermicro UL CSA UL CSA Supermicro UL C...

Страница 121: ...sur le code pour tous les autres appareils lectriques sauf les produits d sign s par Supermicro seulement AC AC UL CSA UL CSA Supermicro UL CSA UL CSA Supermicro Advertencia Cuando instale el producto...

Страница 122: ...nsluitmethode deze moet altijd voldoen aan de lokale voorschriften en veiligheidsnormen inclusief de juiste kabeldikte en stekker Het gebruik van niet geschikte Kabels en of Adapters kan een storing o...

Страница 123: ...ng slots Networking per node One PCI E 4 0 x16 x1 SIOM networking slot Motherboard One H12SST PS per node proprietary form factor 18 86 L x 6 8 W 479 04 mm x 172 72 mm Chassis SC827HQ R2K04BP2 2U rack...

Страница 124: ...ss A and GB17625 1 2012 Safety CSA EN IEC UL 60950 1 Compliant UL or CSA Listed USA and Canada CE Marking Europe Other VCCI CISPR 32 and AS NZS CISPR 32 Environmental Directive 2011 65 EU Delegated Di...