20
Step 4. FIELD WIRING
CAUTION: Label all wires prior to disconnection when servic-
ing controls. Wiring errors can cause improper and dangerous
operation.
ATTENTION: Au moment de l'entretien des commandes,
étiquetez tous les fils avant de les débrancher. Des erreurs
de cáblage peuvent entraîner un fonctionnement inadéquat
et dangereux.
Verify proper operation after servicing.
S'assurer que l'appareil fonctionne adéquatement une fois
l'entretien terminé.
CAUTION: Ground supply lead must be connected to the wire
attached to the green ground screw located on the outlet box.
See
Figures 27 and 28 on Page 21
. Failure to do so will result
in a potential safety hazard. The appliance must be electrically
grounded in accordance with local codes or, in the absence of
local codes, the (USA) National Electrical Code, ANSI/NFPA
70 - latest edition, or the Canadian Electrical Code, CSA C22.1
- latest edition.
Route Cable
NOTE: Electrical wiring must be performed by a qualified electrician.
• Install the strain relief in the hole provided on the right side of fireplace
for the electrical wiring (see
Figure 20
)
.
• Either use the intgrated junction box, or position an electrical junction
box (not provided) within reach of the termination wiring pigtail (see
Figure 23 on Page 21
)
. Route the pigtail to the junction box as the
termination is installed.
• Route 14 gage AWG grounded solid wire Romex
®
or equally-sized
stranded cable (e.g., SJOT) from the fireplace to the newly installed
junction box near the termination. Ensure the cable is safety plated
to prevent damage from framing nails and finish drywall screws.
Route it into the lower control compartment and cut to length before
installing the terminals. Install provided hardware on the ends of
the cable. Cable is not provided. The provided crimp terminals are
intended for use with stranded cable. If using Romex, connect per
National Electric Code or local code.
14 Gage
Grounded
Romex or
similar
Stranded
Cable
Strain
Relief
Vacuum
Hose
Snap
Bushing
Wall Switch
Harness
Junction Box
Right Side
of Fireplace
Probe (1 *)
Hose Clamp (7 *)
Vacuum Hose (2 *)
* See Figure 11 on Page 14
Adaptor Assembly
Pressure Switch
Pressure Switch
Vacuum Hose
Firebox
Pressure switch is located
behind the panel on the right
side of firebox
Vacuum Hose
• Refer to
Figure 25 on Page 21
and install the electrical hardware on
the ends of the cable. Male terminals on the Black and White wires,
and ring terminals on the ground wire.
• Using standard electrical practices and the terminals provided, con-
nect the three wires of the cable to the termination pigtail within the
Electrical junction box. Ensure ground.
• The fireplace end of the cable will be addressed in
Connecting The
Power Vent To The Fireplace Control System
.
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Figure 20 - Routing Wiring
Figure 21 - Vacuum Hose Connection to Probe
Figure 22 - Vacuum Hose Connection to Pressure Switch
NOTE: Pressure switch style may vary from that shown.
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340TYN AND DRT6345TYN) • INSTALLATION INSTRUCTIONS
f i r e - p a r t s . c o m