Valor Sunfire 337 Скачать руководство пользователя страница 1

5109300/01

OWNER GUIDE

This guide is intended to help you care for your gas fire. Please read thoroughly before

using and keep for future reference

This guide to be left with the owner

© Valor Heating

THIS APPLIANCE IS FOR USE WITH NATURAL GAS (G20)

THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM (GB) AND THE

REPUBLIC OF IRELAND (IE) ONLY.

S u n f i r e

MODEL 337

(GC No. 32-032-31)

RADIANT/CONVECTOR 

GAS FIRES 

Manufactured exclusively for British Gas & Scottish Gas by Valor Heating

For Service Phone 0845 950 0400

Содержание Sunfire 337

Страница 1: ...guide to be left with the owner Valor Heating THIS APPLIANCE IS FOR USE WITH NATURAL GAS G20 THIS APPLIANCE IS FOR USE IN THE UNITED KINGDOM GB AND THE REPUBLIC OF IRELAND IE ONLY S u n f i r e MODEL...

Страница 2: ...s a member of the Society of British Gas Industries which works to ensure high standards of safety quality and performance Careful Installation The manufacturer is a CORGI registered company All our g...

Страница 3: ...ars trouble free service Your owner guide aims to improve your understanding and appreciation of your gas fire by providing simple and informative instructions to ensure that you benefit from the exce...

Страница 4: ...rance is necessary to allow the case to be lifted off for servicing and also allows sufficient access to operate the control knob For a shelf made from wood or other combustible materials deeper than...

Страница 5: ...d when close to a heating appliance Please bear this in mind whenever you are considering redecorating Provide a minimum clearance of 50mm between the outer case sides and any corner wall having combu...

Страница 6: ...APPLIANCE DIMENSIONS Page 6 OWNER GUIDE Figure 1 Dimensions clearances...

Страница 7: ...when the fire is hot or if the fire is turned off when hot always wait at least three minutes before attempting to relight To light the fire The control is shown in Figure 2 Depress the control knob...

Страница 8: ...g with a match or taper Depress the control knob and turn anticlockwise towards the 1 IGN position While keeping the knob depressed light the pilot by inserting a long match or taper into the pilot vi...

Страница 9: ...to remove the radiants Remove the dress guard by pressing down the two hooks at the top Tilt the guard forward and lift out Lift the radiant upward to clear the metal retaining bar then pull out botto...

Страница 10: ...t fumes In the United Kingdom it is the law that a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a...

Отзывы: