22
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Step 5. REMOVE THE GLASS DOOR
ASSEMBLY
Refer to
Figure 39 on Page 26
and remove the
front glass door assembly as follows:
Barrier (see Notice, Page 40)
This fireplace comes with a barrier to reduce the
likelihood of burns from touching hot glass. If
the barrier is damaged, the fireplace should be
turned off immediately and the fireplace must
not be operated until a new, approved factory
barrier for this unit is installed.
To remove barrier follow these steps.
A.Lift barrier up by the frame at the top.
B.Remove lower filler piece by pulling down
off of the barrier.
C.Lower barrier and push barrier to left to
release right side.
D.Pull the right side out of fireplace.
E.Remove barrier.
Using a Phillips screwdriver, unfasten the two
(2) screws located at the top of the glass door
assembly.
Tilt the glass door assembly at the top away
from the unit. Lift it carefully off the bottom
door track and set the glass door assembly
aside, protecting it from inadvertent damage.
WARNING
•
Handle this glass with extreme
care! Glass is susceptible to
damage - Do not scratch or
handle roughly.
•
Do not attempt to substitute the
materials used on this door,
or replace cracked or broken
glass with any materials other
than those provided by the
appliance manufacturer.
•
The glass door of this appliance
must only be replaced as a
complete unit as provided
by the manufacturer. Do not
attempt to replace broken,
cracked, or chipped glass
separately.
Factory Wired
Field Wired
Junction Box
Tab Intact
Tab
Intact
n e
e r
G -
d n
u o r
G
e t i
h
W - l
a r t
u e
N 120 VAC - Black
Green
Ground
Screw
Whit
e
Gree
n
Neutral
Side
Hot
Side
Red
Black
Figure 28 - Junction Box Wiring -
120 V, 60 hz, 1-phase
580489-01
Pilot Tube
Spark
Electrode
Flame
Sensor
IPI Pilot
885 Valve
Optional
Split Flow
BL
W
Y
Y
BR
G
O
O
R
R
B
B
G
GR
R
B
BL
WH
B
B
W
G
Battery Holder w/Switch
ON/ Remote
/OFF
Battery Holder
Wire Harness
Reset Switch
(See instructions.)
Power Vent Blower
Power Vent
Models Only
Air Pressure Switch
Power Vent Only
Note: On models
without pressure
switch, these
connectors are
plugged together.
Main Wire
Harness
Main Power Cord
Control Module
G
B
G
W
B
Fuse
ELECTRONIC WIRING DIAGRAM
Ground Y
B
Battery Holder with Switch
ON/Remote/OFF
(Schematic representation only)
COLOR CODE:
B = Black
BB = Brown w/Black Stripe
BG = Brown w/Green Stripe
BL = Blue
BR = Brown
G = Green
GY = Gray
O = Orange
R = Red
W = White
Y = Yellow
Figure 27 - Electronic Wiring Diagram
INNOVATIVE HEARTH PRODUCTS • POWER VENT DV GAS FIREPLACES (DRT6340TYN AND DRT6345TYN) • INSTALLATION INSTRUCTIONS